Service and Installation Manual

Please read this manual completely before attempting to install or operate this equipment!  
Notify carrier of damage!  Inspect all components immediately.  See page 2.

Refrigerated, Heated and Non-Electrical Units

Effective March 2003

IMPORTA

NT INFOR

MATION

READ BEF

ORE USE

PLEASE S

AVE THES

E INSTRU

CTIONS!

CAUTION

Summary of Contents for Shelleymatic SH2C-74-NU

Page 1: ...completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Refrigerated Heated and Non Electrical Units Effective March 2...

Page 2: ...ilding 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents wit...

Page 3: ...115 5 15P 5 0 Shelleyglas MODEL VOLTAGE NEMA NUMBER HERTZ PHASE PLUG AMP Heated Serving Counters SH 2 120 208 230 60 1 14 20P 15 0 SH 3 120 208 230 60 1 14 30P 20 0 SH 4 120 208 230 60 1 14 50P 26 0...

Page 4: ...ation This provides more uniform temperature for the sauce Product temperature should range from 140 F to 160 F Never place food directly in well Always use pans For most efficient operation keep cove...

Page 5: ...unit should be plugged into a receptacle with its own circuit protection that matches the amperage of the plug Refer to the amperage data on page 3 or the serial tag data and your local code or the N...

Page 6: ...e oil Recommended maintenance schedule Daily Wipe and or wash food wells unit surface any refrigerated understorage and door gaskets Monthly Remove louvers and clean condensing coil with a soft brush...

Page 7: ...NT HEATING 120V 1000W 5 THERMOSTAT NON ADJ 550 F 6 INSULATION BLANKET 7 KNOB INFINITE CONTROL CONTROL INFINITE 240V 15A CONTROL INFINITE 120V 15A PLATE DEFLECTOR DFW W DRAIN FOOD WELL W STRAPS W DRAIN...

Page 8: ...PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FOOD WELL FOOD WELL L2 L1 P H2 H1 INFI...

Page 9: ...MASTER ON OFF SWITCH 1 PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FO...

Page 10: ...or customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 10 WIRING DIAGRAM COLD PAN COMBO WIRING DIAGRAM KCSC SCSC KCFT AND SCFT COLD PANS PLEASE REFER TO PAGES 8 AND 9 FOR...

Page 11: ...s Shelleysteel Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com WIRING DIAGRAM KCFM SCFM UNITS SUPPLIED WITH EVAPORATOR PRESSURE...

Page 12: ...O REPLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Swit...

Page 13: ...ng 6150201 Extension Spring 3234188 Large Lid KCF 50 KCF 60 3234242 Plastic Drain 6320007 Bearing 6150201 Extension Spring 3234188 Large Lid 3526709 Conditioning Unit 3516101 Filter Dryer 3516225 Expa...

Page 14: ...ED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part i...

Page 15: ...affect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where...

Page 16: ...l free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Re...