INSTALLATION: REFRIGERATED UNITS

Location

Be sure the location chosen has a floor strong enough to 

support the total weight of the cabinet and contents. Reinforce 

the floor as necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good 

air circulation inside and out.

Inside cabinet

: Do not pack unit so full that air cannot 

circulate. Take care not to block air flow to the fans and 

allow space along the sides.

Outside cabinet

: Be sure the unit has access to ample air; 

avoid hot corners and locations near stoves and ovens. It 

is suggested the rear of the unit be no less than two inches 

from any wall, partition or any other object which will 

restrict exhaust air flow.

Leveling

A level cabinet looks better and will perform better because 

the doors will line up with the door frames properly, and the 

cabinet will not be subject to unnecessary strain.

Stabilizing

Some models are supplied on casters for your convenience, 

for ease of cleaning underneath and mobility.

 

The unit must be installed in a stable condition 

with the front wheels locked, locking the front 

casters after installation is the owner’s and 

operator’s responsibility.

Plumbing

Refrigerated units have a drain that exits the unit on the 

bottom, and is located on the operator’s left side. Standard 

units on casters or legs will have a bronze faucet that fits a 

standard garden hose. Units on legs with optional remote drain 

valve handle will have 1” threaded pipe extending from bottom 

of unit. On standard units, a stainless steel access panel or 

hinged louver will be provided for access to drain connections.

 Moisture collecting from improper drainage 

can create a slippery surface on the floor and 

a hazard to employees. It is the owner’s and 

operator’s responsibility to provide a container or 

outlet for drainage.

Electrical connection

A standard refrigerated unit is provided with a power cord 

and 3-prong grounded plug.
The unit should be plugged into a receptacle with its own 

circuit protection that matches the amperage of the plug.

 Refer to the amperage data on page 3 or the 

serial tag data and your local code or the National 

Electrical Code to be sure the unit is connected 

to the proper power source. A protected circuit 

of the correct voltage and amperage must be run 

for connection of the supply cord or permanent 

connection to the unit.
 On cord-connected units, an ON/OFF switch is 

located directly on the face of the compressor 

section. The switch must be turned to its OFF position and 

power supply disconnected whenever doing the following:
   1. 

Performing maintenance functions.

   2. 

Cleaning the refrigerated cabinet area.

   3. 

Performing service or repair functions.

 Under no circumstances should the unit be operated 

without the louvered panel in place.

CAUTION

OPERATION LIQUITEC UNITS

LiquiTec Series cold pans are adjusted at the factory to provide 

satisfactory operation without any further adjustments.  

However, if it is necessary to adjust the temperature, the 

control is located in the machine compartment.  Turn the knob 

clockwise as indicated on the control.  Settings are from 1 

through 7; 7 being the coldest.  Adjustments should be made 

gradually.  Several small adjustments will be more effective 

than one large adjustment.  It may take an hour or longer to 

realize the temperature change depending on the application 

and location of the unit.

These units are not designed to cool warm food products.  

Items should be placed in the unit pre-cooled at least to the 

desired holding temperature, if not slightly colder.  In some 

applications, a gradual warming of product may occur, particu-

larly at the exposed top of the products.  Stirring or rotation of 

the product may be necessary to maintain overall temperature.  

Warming of food product can occur very quickly outside of 

the unit.  When loading or rotating the product, avoid leaving 

food items in a non-refrigerated location for any length of time 

to prevent warming or spoilage.

The temperature control is used to turn the unit on and off as 

well as control the temperature of the cold pan.  The settings 

range from 1 to 7; 7 being the coldest.  To turn the cold pan 

off, turn the knob to the off position.  

The cold pan is not intended to be used with ice.

Summary of Contents for Shelleymatic SH2C-74-NU

Page 1: ...completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Refrigerated Heated and Non Electrical Units Effective March 2...

Page 2: ...ilding 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents wit...

Page 3: ...115 5 15P 5 0 Shelleyglas MODEL VOLTAGE NEMA NUMBER HERTZ PHASE PLUG AMP Heated Serving Counters SH 2 120 208 230 60 1 14 20P 15 0 SH 3 120 208 230 60 1 14 30P 20 0 SH 4 120 208 230 60 1 14 50P 26 0...

Page 4: ...ation This provides more uniform temperature for the sauce Product temperature should range from 140 F to 160 F Never place food directly in well Always use pans For most efficient operation keep cove...

Page 5: ...unit should be plugged into a receptacle with its own circuit protection that matches the amperage of the plug Refer to the amperage data on page 3 or the serial tag data and your local code or the N...

Page 6: ...e oil Recommended maintenance schedule Daily Wipe and or wash food wells unit surface any refrigerated understorage and door gaskets Monthly Remove louvers and clean condensing coil with a soft brush...

Page 7: ...NT HEATING 120V 1000W 5 THERMOSTAT NON ADJ 550 F 6 INSULATION BLANKET 7 KNOB INFINITE CONTROL CONTROL INFINITE 240V 15A CONTROL INFINITE 120V 15A PLATE DEFLECTOR DFW W DRAIN FOOD WELL W STRAPS W DRAIN...

Page 8: ...PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FOOD WELL FOOD WELL L2 L1 P H2 H1 INFI...

Page 9: ...MASTER ON OFF SWITCH 1 PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FO...

Page 10: ...or customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 10 WIRING DIAGRAM COLD PAN COMBO WIRING DIAGRAM KCSC SCSC KCFT AND SCFT COLD PANS PLEASE REFER TO PAGES 8 AND 9 FOR...

Page 11: ...s Shelleysteel Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com WIRING DIAGRAM KCFM SCFM UNITS SUPPLIED WITH EVAPORATOR PRESSURE...

Page 12: ...O REPLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Swit...

Page 13: ...ng 6150201 Extension Spring 3234188 Large Lid KCF 50 KCF 60 3234242 Plastic Drain 6320007 Bearing 6150201 Extension Spring 3234188 Large Lid 3526709 Conditioning Unit 3516101 Filter Dryer 3516225 Expa...

Page 14: ...ED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part i...

Page 15: ...affect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where...

Page 16: ...l free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Re...

Reviews: