If your unit is 

heated

, the serial tag is located above the 

louvered panel near the on/off switch.

Refrigerated

 units have the serial tag located in the 

compressor area near the on/off switch.

Understorage

 units often have the serial tag located on the 

left inside the storage area.

All purpose counters, utility equipment or delivery carts

 do 

not require serial numbers but a model tag is placed at the 

top of the pylon on the back of the unit.

Always have the serial number of your unit available when 

calling for parts or service. 

This manual covers standard units only. If you have a 

custom unit, consult the customer service department at the 

number listed below.

©2003 The Delfield Company. All rights reserved. Reproduction without 

written permission is prohibited.
“Delfield” is a registered trademarks of The Delfield Company.

CONTENTS

SERIAL NUMBER INFORMATION

RECEIVING AND INSPECTING THE EQUIPMENT

RECEIVING & INSPECTING EQUIPMENT .................................2

SPECIFICATIONS........................................................................3

INSTALLATION ..........................................................................4

OPERATION.............................................................................4-5

MAINTENANCE ..........................................................................6

CLEANING LIQUITEC .................................................................7

FOOD WELL ASSEMBLY............................................................7

WIRING DIAGRAM .................................................................8-9

STANDARD LABOR GUIDELINES............................................10

REPLACEMENT PARTS LIST...................................................11

STANDARD WARRANTY..........................................................11

PARTS DEPOTS ........................................................BACK PAGE

Even though most equipment is shipped crated, care should 

be taken during unloading so the equipment is not damaged 

while being moved into the building.

1.  Visually inspect the exterior of the package and skid or  

container.  Any damage should be noted and reported 

to the delivering carrier immediately.

2.  If damaged, open and inspect the contents with the 

carrier.

3.  In the event that the exterior is not damaged, yet upon 

opening, there is concealed damage to the equipment 

notify the carrier.  Notification should be made verbally 

as well as in written form.

4.  Request an inspection by the shipping company of the 

damaged equipment.  This should be done within 10 

days from receipt of the equipment.

5.  Check the lower portion of the unit to be sure legs or 

casters are not bent.

6.  Also open the compressor compartment housing and 

visually inspect the refrigeration package.  Be sure lines 

are secure and base is still intact.

7.  Freight carriers can supply the necessary damage forms 

upon request.

8.  Retain all crating material until an inspection has been 

made or waived.

The units with LiquiTec technology cold pans con-

tain a non-toxic eutectic fluid within a sealed inner 

liner.  This fluid may leak if the tank is punctured 

so care must be taken when uncrating and setting 

in place.  The eutectic fluid is non-toxic and may be 

flushed down a disposal drain.  If the LiquiTec unit 

cold pans leak, immediately call the Delfield service 

department directly at 1-800-733-8821 not your 

local service agent.

Uncrating the Equipment

First cut and remove the banding from around the crate.  

Remove the front of the crate material, use of some tools will 

be required.  If the unit is on legs remove the top of the crate 

as well and lift the unit off the skid.  If the unit is on casters 

it can be "rolled" off the skid.

Summary of Contents for Shelleymatic SH2C-74-NU

Page 1: ...completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Refrigerated Heated and Non Electrical Units Effective March 2...

Page 2: ...ilding 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents wit...

Page 3: ...115 5 15P 5 0 Shelleyglas MODEL VOLTAGE NEMA NUMBER HERTZ PHASE PLUG AMP Heated Serving Counters SH 2 120 208 230 60 1 14 20P 15 0 SH 3 120 208 230 60 1 14 30P 20 0 SH 4 120 208 230 60 1 14 50P 26 0...

Page 4: ...ation This provides more uniform temperature for the sauce Product temperature should range from 140 F to 160 F Never place food directly in well Always use pans For most efficient operation keep cove...

Page 5: ...unit should be plugged into a receptacle with its own circuit protection that matches the amperage of the plug Refer to the amperage data on page 3 or the serial tag data and your local code or the N...

Page 6: ...e oil Recommended maintenance schedule Daily Wipe and or wash food wells unit surface any refrigerated understorage and door gaskets Monthly Remove louvers and clean condensing coil with a soft brush...

Page 7: ...NT HEATING 120V 1000W 5 THERMOSTAT NON ADJ 550 F 6 INSULATION BLANKET 7 KNOB INFINITE CONTROL CONTROL INFINITE 240V 15A CONTROL INFINITE 120V 15A PLATE DEFLECTOR DFW W DRAIN FOOD WELL W STRAPS W DRAIN...

Page 8: ...PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FOOD WELL FOOD WELL L2 L1 P H2 H1 INFI...

Page 9: ...MASTER ON OFF SWITCH 1 PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FO...

Page 10: ...or customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 10 WIRING DIAGRAM COLD PAN COMBO WIRING DIAGRAM KCSC SCSC KCFT AND SCFT COLD PANS PLEASE REFER TO PAGES 8 AND 9 FOR...

Page 11: ...s Shelleysteel Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com WIRING DIAGRAM KCFM SCFM UNITS SUPPLIED WITH EVAPORATOR PRESSURE...

Page 12: ...O REPLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Swit...

Page 13: ...ng 6150201 Extension Spring 3234188 Large Lid KCF 50 KCF 60 3234242 Plastic Drain 6320007 Bearing 6150201 Extension Spring 3234188 Large Lid 3526709 Conditioning Unit 3516101 Filter Dryer 3516225 Expa...

Page 14: ...ED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part i...

Page 15: ...affect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where...

Page 16: ...l free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Re...

Reviews: