MAINTENANCE

Defrosting

Refrigerated cold pans and frost tops should be defrosted 

daily.  Milk or Ice Cream dispensers require defrosting after 

3/8” to 1/2” of frost forming.  On/Off switch located above 

louver panel.

 Never use sharp objects or tools to clean or 

scrape ice/frost build up from the refrigerated 

cold pans or frost tops.  A puncture to the 

pan could cause irreparable damage to the 

refrigeration system.

Units with a Eutectic Fluid Cold Pan require the 

same precautions.  The fluid is NOT refillable 

and loss of fluid due to a puncture would cause 

irreparable damage.  

Over shelves and other items mounted to the top of the 

counters should never be installed in the field due to the 

potential damage to the refrigeration system.

Cleaning the unit

To clean refrigerated understorage, use mild soap and water.

For all fiberglass and stainless steel parts, use a mild, non-

abrasive soap or detergent and warm water. This may be 

followed by an application of stainless steel cleaner or polish 

which will eliminate water spotting, fingerprints and bring 

out the color of the fiberglass.

To maintain the rich, brilliant color of the fiberglass and to 

remove shallow surface scratches, wax twice a year. This can 

be done in the same manner in which a car is waxed.

Casters

Casters can be lubricated with penetrating type oil.

Recommended maintenance schedule

Daily: 

Wipe and/or wash food wells, unit surface, any 

refrigerated understorage and door gaskets.

Monthly:

 Remove louvers and clean condensing coil with 

a soft brush, such as a fin comb, or vacuum cleaner brush 

attachment. The object is to remove dust and webs from 

fins without bending them. Check casters for any debris that 

could be binding the wheels such as strings from mops or 

bits of paper.

Every six months:

 Wax fiberglass body and if necessary, 

lubricate casters.

All Delfield refrigerated models come equipped with 

115-volt, 60 cycle, single phase refrigeration units. The 

refrigeration valves are open and ready to operate as soon 

as the power supply cord is plugged into the standard 115-

volt, grounded electrical outlet.

Pressure Control

The temperature is controlled by an adjustable pressure 

control located in the machine compartment. An adjustable 

control has the word 

COLDER

 near the knob, with an arrow 

to indicate the adjustment direction. These controls are 

field adjustable and do not require a service agent. If you 

have any questions, feel free to contact the Delfield Service 

Department.

 In attempting to adjust the pressure control, 

you can do damage to your unit by accidentally 

adjusting the differential. Please make small 

incremental adjustments if a temperature 

adjustment is necessary, please contact the 

service department at Delfield (800) 733-8821 

or your local service agent. Delfield is not responsible 

for charges incurred while having the pressure control 

adjusted.

PRESSURE CONTROL SETTINGS

Pressure control settings:

KCSC/SCSC, KHCR/SHCR & KCFT/SCFT 
 

28# cut in 18# cut out

KCM/SCM
 

35# cut in 15# cut out

Summary of Contents for Shelleymatic SH2C-74-NU

Page 1: ...completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Refrigerated Heated and Non Electrical Units Effective March 2...

Page 2: ...ilding 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents wit...

Page 3: ...115 5 15P 5 0 Shelleyglas MODEL VOLTAGE NEMA NUMBER HERTZ PHASE PLUG AMP Heated Serving Counters SH 2 120 208 230 60 1 14 20P 15 0 SH 3 120 208 230 60 1 14 30P 20 0 SH 4 120 208 230 60 1 14 50P 26 0...

Page 4: ...ation This provides more uniform temperature for the sauce Product temperature should range from 140 F to 160 F Never place food directly in well Always use pans For most efficient operation keep cove...

Page 5: ...unit should be plugged into a receptacle with its own circuit protection that matches the amperage of the plug Refer to the amperage data on page 3 or the serial tag data and your local code or the N...

Page 6: ...e oil Recommended maintenance schedule Daily Wipe and or wash food wells unit surface any refrigerated understorage and door gaskets Monthly Remove louvers and clean condensing coil with a soft brush...

Page 7: ...NT HEATING 120V 1000W 5 THERMOSTAT NON ADJ 550 F 6 INSULATION BLANKET 7 KNOB INFINITE CONTROL CONTROL INFINITE 240V 15A CONTROL INFINITE 120V 15A PLATE DEFLECTOR DFW W DRAIN FOOD WELL W STRAPS W DRAIN...

Page 8: ...PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FOOD WELL FOOD WELL L2 L1 P H2 H1 INFI...

Page 9: ...MASTER ON OFF SWITCH 1 PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT L2 L1 P H2 HL INFINITE CONTROL HEATER LIMIT SWITCH L2 L1 P H2 H1 INFINITE CONTROL HEATER LIMIT SWITCH FO...

Page 10: ...or customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 10 WIRING DIAGRAM COLD PAN COMBO WIRING DIAGRAM KCSC SCSC KCFT AND SCFT COLD PANS PLEASE REFER TO PAGES 8 AND 9 FOR...

Page 11: ...s Shelleysteel Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com WIRING DIAGRAM KCFM SCFM UNITS SUPPLIED WITH EVAPORATOR PRESSURE...

Page 12: ...O REPLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Swit...

Page 13: ...ng 6150201 Extension Spring 3234188 Large Lid KCF 50 KCF 60 3234242 Plastic Drain 6320007 Bearing 6150201 Extension Spring 3234188 Large Lid 3526709 Conditioning Unit 3516101 Filter Dryer 3516225 Expa...

Page 14: ...ED TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part i...

Page 15: ...affect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where...

Page 16: ...l free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Re...

Reviews: