Service Manual Chapter6. Safe Unit
©
Nautilus Hyosung, Inc.
All Rights Reserved.
6-3
10. EnF -> Enter New Combination -> Cnf
Select and enter the new combination. “CnF” (confirm new Factory combination) will
be displayed
11. Cnf -> Enter New Combination -> POC
Enter new combination again to confirm. POC (Pull Out Change key) will be
displayed.
12. POC -> Remove Change Key -> EOP
Remove the change key. EOP (End Operation) is displayed.
13. EOP -> Power Lock -> EC
Turn the dial to the left (CCW)until EC (Enter Combination) is displayed.
14. EC -> Enter New Shelved Mode Combination -> OPr
Enter the new shelved mode combination by pressing those digits on the lock’s
keypad. The numbers will be displayed on the LCD as they are entered
15. OPr -> Retract Bolt
Turn the Dial to the right (CW) to retract the bolt.
16. Close Door
17. Extend Bolt
Turn the Dial to the left (CCW) to extend the bolt.