Chapter8. CDU (Cash Dispenser Unit) Service Manual
8-16
©
Nautilus Hyosung, Inc.
All Rights Reserved.
2. Gate Operation Detection Sensor & Encoder Sensor
1) CS3
①
Remove the M3 screw of the CS3 sensor bracket (1 place).
②
Remove the connector and the cable tie to remove the sensor bracket. Be
careful not to break the connector pin when removing.
③
Press the part
②
of the sensor gently as shown in the figure below to remove
the lock and the sensor.
④
To insert the sensor, insert the part
①
first, and then press part
②
to lock.
⑤
Assemble in the reverse order -
③
~
①
.
<Note!>
When reassembling the CS3, pull the solenoid and adjust the detection bracket to