background image

megacount.io

PEOPLE COUNTER

User Manual

OMEGA-USB

Summary of Contents for OMEGA-USB

Page 1: ...megacount io PEOPLE COUNTER User Manual OMEGA USB ...

Page 2: ...by MEGACOUNT Ltd Disclaimer MEGACOUNT Ltd ensures that the contents of this document are accurate and complete but is not legally responsible for the information provided The user is fully responsible for using this document and for all following results MEGACOUNT reserves the right to change the contents of this document without prior notice 1 Design and characteristics of the device can be chang...

Page 3: ...LING BATTERIES WRONG POLARITY CAN LEAD TO COUNTERS BREAKING AND BATTERIES OVERHEATING TO AVOID DAMAGE THAT CAN CAUSE A FIRE OR ELECTROCUTION KEEP THE DEVICE AWAY FROM WATER RAIN AND HIGH HUMIDITY IT IS PROHIBITED TO INSERT ANY METALLIC OBJECTS INTO THE CASING OF THE DEVICE OR ANY HOLES OR SOCKETS IN THE DEVICE CASING 3 ...

Page 4: ...TING THE COUNTER TO THE USB MODEM 13 STEP 4 SETTING THE DISTANCE BETWEEN THE COUNTERS 14 STEP 5 MOUNTING THE COUNTERS TO THE SUFRFACE 15 STEP 6 COUNTER CONFIGURATION 16 STEP 7 DATA EXPORT 17 STEP 7 7 1 SETTING UP OMEGA CLOUD ANALYTICS 18 STEP 7 7 2 SETTING HTTP S DATA TRANSFER 19 STEP 7 7 3 SETTING EMAIL DATA TRANSFER 20 STEP 7 7 4 SETTING FTP sFTP SSH DATA TRANSFER 21 RECOMMENDATIONS AND TROUBLES...

Page 5: ...ing the counter on a surface Adhesive pads type 2 2 Pads for mounting the counter on a surface Screws 4 Screws for mounting the counter on a surface USB cable 1 USB cable for data transfer to the modem Quick Guide 1 Online manual MEGACOUNT There is one pair of counters in the basic kit Additional counter pairs can be supplied for connecting to the USB modem through the radio channel Up to 100 coun...

Page 6: ...rected at each other they create two beams between them Each time the beams are crossed block R detects the fact of crossing and its direction stores that data and later transfers it to the Ethernet modem as pictured below COUNTER BLOCK R COUNTER BLOCK T Radio channel up to 200 m 2 4 Mhz carrier frequency Infrared beams 990 nm Direction of the people flow Top view USB radio modem USB Server HTTP H...

Page 7: ...he ETH modem see the manual Infrared band 990 nm Dimensions 42 mm height 68 mm length 18 mm width Direction indicator Bi directional counting BLUE RED Unidirectional counting BLUE RED Photovoltaic cells Built in radio transmitter MEGACOUNT COUNTER BLOCK T Photovoltaic cells The supporting T block enables infrared lighting and contains a microprocessor and a chain of photovoltaic cells that are nee...

Page 8: ... EMAIL Data export protocol OMEGA XML JSON TXT Modem interface USB through operating systems WINDOWS LINUX iOS Power supply АА 1 5 V batteries 2 per each counter block Battery change is carried out by the user Power consumption 60 µA Delivery kit People counters 2 blocks R T USB modem 1 pc Adhesive pads 4 pcs L brackets 2 pcs Screws 4 pcs USB cable 1 pc АА 1 5 V batteries 4 pcs Operating time on a...

Page 9: ...PC and wait for modem drivers to install If everything is done correctly the interface will look like this DEFAULT PASSWORD 18318 To change the password use the password changing option in Menu Password USB MODEM IS CONNECTED SERVICE IS WORKING OBLIGATORY CONDITIONS FOR FURTHER CONFIGURATION If the program says that service is not working check anti virus software and allow the program there then ...

Page 10: ...Protective black screen Opening the casing Installing batteries in blocks R and T Install batteries into holders with correct polarity as shown on the picture below POLARITY MUST BE FOLLOWED CORRECTLY IF IT IS WRONG DEVICE OVERHEATING AND LOSS OF FUNCTION ARE POSSIBLE WHICH ARE NOT COVERED BY WARRANTY If everything is installed correctly the indicator on the counter will blink If the indicator is ...

Page 11: ...below Press the button at the moment when the program is scanning This process is only done for the R block 11 Software preparations Launch OMEGA USB control shell from the Desktop or through System tray and go to Menu Add counter A window for connecting the modem with the counter will open Click the SCAN button in the program and press the SERVICE button on the R block while the program is scanni...

Page 12: ... T block Connecting additional counters and adding them to OMEGA USB program If there are additional pairs of counters follow the same connection process as described before for the R blocks for the additional pairs and rename them in the program according to their location One entry indicates one pair of counters R block and T block Example One entrance with one pair two blocks there will be one ...

Page 13: ...ssary to configure the T block by setting the correct distance between the blocks Open the casing of the T block and set the distance on it by moving the correct switch to the right as shown on the pictures below Example for installation with a 2m distance Example for installation with a 3m distance 13 ...

Page 14: ...icture below Main recommendation when mounting counters blocks fix the counters so that the R block is facing the ETH modem When mounting the counters mind the door handles they should not be in the counters operating field When mounting the counters mind the daylight it is not recommended to install counters under direct sunlight at any time of the day It is recommended to install the counters fu...

Page 15: ...h indicators blink simultaneously no need to additionally divide end values by two Entrance indicator If the indicator is red when someone enters put in RED if the indicator is blue when someone enters put in BLUE Important Data transmission Optimal interval is every 5 8 hours The bigger the interval the more battery is saved Operating time The counter is set up to work around the clock by default...

Page 16: ...onnecting the counter to cloud analytics with the possibility to view data via any browser and smartphone HTTP S packet data transfer in JSON or XML format to a server that supports TLS encryption FTP sFTP SSH file data transfer in JSON XML TXT formats to a server that supports safe sFTP EMAIL data transfer in JSON or XML format to email This will open the panel with server types for data export 1...

Page 17: ...END A REQUEST TO info megacount io When you are connected to the analytics program it will be possible to view data with a browser on any PC laptop or smartphone Name Any name ID for the data export e g Analytics My data export etc Server Will be provided with the response to your request Port Will be provided with the response to your request ID Will be provided with the response to your request ...

Page 18: ... ACCEPTED TEXT MESSAGE ONLY THEN WILL THE PROGRAM SEND THE NEXT DATA PACKET HTTP S settings Name Any name ID for the data export e g Analytics My data export etc Protocol http or https with TLS encryption support Server Server address for receiving packets supports DNS Port Port address of the server to which the data will be pushed URI Receiving script resource ID Data export format JSON transfer...

Page 19: ...ry Port Port address of the server to which the data will be pushed URI Receiving script resource ID Server Port TLS Authentication Login Password Client EMAIL settings Test Put in any email address and click Test if everything is done correctly a test letter will be received on that email address Sending time Every day Time settings for data export Interval Sending interval and time range setting...

Page 20: ...owing end value one day many files File name Compound file name format ID and CD tags are obligatory Port Port address of the server to which the data will be pushed URI Receiving script resource ID Server Port Protocol Login Password Directory FTP Settings Upload to folder with name of the modem s MAC address The program will create a folder with the modem s MAC address on the FTP server and will...

Page 21: ...it for synchronization and check counter performance Both red and blue indicators will be blinking simultaneously There is no need to divide the values by two the counters do all the calculations In values are bigger than Out values and vice versa Check that there are no doors door handles or other objects that can hinder counting If a visitor reaches for the door with their hand to open it it can...

Page 22: ...hat have accepted the recycling system This marking implies prohibition of disposing of the equipment together with other household waste Device contains batteries If disposed of incorrectly batteries can harm a person s health and the environment To protect environmental resources and support recycling of materials it is recommended to store batteries separately from other waste and dispose of th...

Page 23: ... as intended indoors under normal conditions Service life 7 years Warranty 1 year MEGACOUNT MANUFACTURER MEGACOUNT LTD 73472165005 134 Mendeleeva St UFA 450022 Russia info megacount io megacount io EAC 23 ...