351 – AL Open Load Cylinder B1
ZKP-Number: 1.8004.550
Injector wiring fault, cylinder B1
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder B1.
1. Check injector wiring and solenoid valve.
2. Contact Service.
352 – AL Open Load Cylinder B2
ZKP-Number: 1.8004.551
Injector wiring fault, cylinder B2
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder B2.
1. Check injector wiring and solenoid valve.
2. Contact Service.
353 – AL Open Load Cylinder B3
ZKP-Number: 1.8004.552
Injector wiring fault, cylinder B3
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder B3.
1. Check injector wiring and solenoid valve.
2. Contact Service.
354 – AL Open Load Cylinder B4
ZKP-Number: 1.8004.553
Injector wiring fault, cylinder B4
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder B4.
1. Check injector wiring and solenoid valve.
2. Contact Service.
355 – AL Open Load Cylinder B5
ZKP-Number: 1.8004.554
Injector wiring fault, cylinder B5
Yellow alarm – misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder B5.
1. Check injector wiring and solenoid valve.
2. Contact Service.
66 | Troubleshooting | MS150112/01E 2014-10
TIM-ID: 0000029153 - 005