206 – SD T-Exhaust A
ZKP-Number: 1.8004.576
Signal error, exhaust temperature sensor on A-side
Yellow alarm – warning
Cause
Corrective action
Exhaust temperature sensor on
A-side faulty.
Short circuit or wire break.
1. Check sensor and cabling (B4.21), replace as necessary
(→ Page 189).
2. Fault is rectified when engine is restarted (→ Page 29).
3. Contact Service.
207 – SD T-Exhaust B
ZKP-Number: 1.8004.577
Signal error, exhaust temperature sensor on B-side
Yellow alarm – warning
Cause
Corrective action
Exhaust temperature sensor on
B-side faulty.
Short circuit or wire break.
1. Check sensor and cabling (B4.22), replace as necessary
(→ Page 189).
2. Fault is rectified when engine is restarted (→ Page 29).
3. Contact Service.
208 – SD P-Charge Air
ZKP-Number: 1.8004.566
Charge-air pressure sensor signal error
Yellow alarm – warning
Cause
Corrective action
Charge-air pressure sensor
faulty.
Short circuit or wire break.
1. Check sensor and wiring (B10), replace as necessary
(→ Page 189).
2. Fault is rectified when engine is restarted (→ Page 29).
3. Contact Service.
211 – SD P-Lube Oil
ZKP-Number: 1.8004.563
Lube oil pressure sensor signal error
Yellow alarm – warning
Cause
Corrective action
Lube oil pressure sensor faulty.
Short circuit or wire break.
1. Check sensor and wiring (B5), replace as necessary
(→ Page 189).
2. Fault is rectified when engine is restarted (→ Page 29).
3. Contact Service.
MS150112/01E 2014-10
| Troubleshooting | 53