336 – AL Wiring Cylinder B6
ZKP-Number: 1.8004.535
Wiring faulty, cylinder B6
Yellow alarm – misfiring
Cause
Corrective action
Short circuit fault in injector
wiring, cylinder B6.
1. Check solenoid valve.
2. Contact Service.
337 – AL Wiring Cylinder B7
ZKP-Number: 1.8004.536
Wiring faulty, cylinder B7
Yellow alarm – misfiring
Cause
Corrective action
Short circuit fault in injector
wiring, cylinder B7.
1. Check solenoid valve.
2. Contact Service.
338 – AL Wiring Cylinder B8
ZKP-Number: 1.8004.537
Wiring faulty, cylinder B8
Yellow alarm – misfiring
Cause
Corrective action
Short circuit fault in injector
wiring, cylinder B8.
1. Check solenoid valve.
2. Contact Service.
339 – AL Wiring Cylinder B9
ZKP-Number: 1.8004.538
Wiring faulty, cylinder B9
Yellow alarm – misfiring
Cause
Corrective action
Short circuit fault in injector
wiring, cylinder B9.
1. Check solenoid valve.
2. Contact Service.
340 – AL Wiring Cylinder B10
ZKP-Number: 1.8004.539
Wiring faulty, cylinder B10
Yellow alarm – misfiring
Cause
Corrective action
Short circuit fault in injector
wiring, cylinder B10.
1. Check solenoid valve.
2. Contact Service.
MS150112/01E 2014-10
| Troubleshooting | 63
TIM-ID: 0000029153 - 005