AirWorks AWK-1131A
Web Console Configuration
3-31
E-mail Server Settings
You can set up to 4 e-mail addresses to receive alarm emails from the AWK-1131A. The following parameters
can be configured on the
E-mail Server Settings
page. In addition, a
Send Test Mail
button can be used to
test whether the Mail server and e-mail addresses work well. More detailed explanations about these
parameters are given after the following figure.
Mail server (SMTP)
Setting
Description
Factory Default
IP address
The IP Address of your email server.
None
User name & Password
Setting
Description
Factory Default
User name and password used in the SMTP server
None
From e-mail address
Setting
Description
Factory Default
Max. 63 characters
Enter the administrator’s e-mail address which will be shown in
the “From” field of a warning e-mail.
None
To E-mail address 1/ 2/ 3/ 4
Setting
Description
Factory Default
Max. 63 characters
Enter the receivers’ e-mail addresses.
None
Trap
Traps can be used to signal abnormal conditions (notifications) to a management station. This trap-driven
notification can make your network more efficient.
Because a management station usually takes care of a large number of devices that have a large number of
objects, it will be overloading for the management station to poll or send requests to query every object on
every device. It would be better if the managed device agent could notify the management station by sending
a message known as a trap for the event.