![Motorola WiNG 5.6 Reference Manual Download Page 972](http://html.mh-extra.com/html/motorola/wing-5-6/wing-5-6_reference-manual_247437972.webp)
14 - 10 WiNG 5.6 Access Point System Reference Guide
DHCPSVR DHCPSVR_STOP 6 DHCP server is stopped
DHCP server stopped
DIAG WD_RESET_SYS 2 The system has been RESET
by the Watchdog
Log watchdog reset
DIAG CPU_USAGE_TOO_HIGH 4 CPU Usage too high.
Limit of [int]*(0.1%) exceeded. Current CPU usage is
[int]*(0.1%)
Log CPU load detected as too high
DIAG CPU_USAGE_TOO_HIGH_RECOVER 4 CPU Usage
too high recover. Limit is [int]*(0.1%)
Current CPU usage is too high
DIAG CPU_LOAD 4 [str] minute average load limit
exceeded, value is [str]% limit is [str]% (top processes:
[str])
CPU average load limit exceeded
DIAG RAM_USAGE 6 [str], pid [uint], has exceeded ram
usage limit [uint].[uint]%, now using [uint].[uint]%
Log processor RAM usage has exceeded RAM limit
DIAG MEM_USAGE_TOO_HIGH 6 Memory Usage too
high. Current Usage is [int]*(0.1%). Memory Usage
Threshold is [int]*(0.1%)
Memory usage too high
DIAG MEM_USAGE_TOO_HIGH_RECOVER 6 Memory
Usage too high recover. Current Usage is [int]*(0.1%).
Memory Usage Threshold is [int]*(0.1%)
Memory usage detected as too high
DIAG BUF_USAGE 6 [uint] byte buffer usage greater
than expected, [uint] used, warning level [uint]
Log buffer usage greater than anticipated
DIAG HEAD_CACHE_USAGE 6 socket buffer head
cache usage is greater than expected, usage [uint],
warning level [uint]
Log head cache usage greater than anticipated
DIAG IP_DEST_USAGE 6 IP destination cache usage is
greater than expected, usage [uint], warning level [uint]
Log destination cache usage greater than anticipated
DIAG FREE_RAM 6 Free RAM, [str]% is less than limit
[str]%. Top Memory process: [str]/[uint] using
[uint].[uint]% , [str]/[uint] using [uint].[uint]% , [str]/[uint]
using [uint].[uint]%
Log RAM space less than limit
DIAG FREE_FLASH_DISK 4 Free [str] file system space,
[str]% is less than limit [str]%
Log free disk space less than limit
DIAG DISK_USAGE 4 Disk usage too high
Log disk usage too high
DIAG NEW_LED_STATE 6 LED state message [str] from
module [str]
Log LED message from module
DIAG FREE_FLASH_INODES 4 [uint] Free INodes on [str]
file system is less than limit [uint]
Log INodes less than system limit
DIAG FREE_NVRAM_DISK 4 Free [str] file system
space, [str]% is less than limit [str]%
Log file system space less than limit
Summary of Contents for WiNG 5.6
Page 1: ...Motorola Solutions WiNG 5 6 ACCESS POINT SYSTEM REFERENCE GUIDE ...
Page 2: ......
Page 22: ...8 WiNG 5 6 Access Point System Reference Guide ...
Page 26: ...1 4 WiNG 5 6 Access Point System Reference Guide ...
Page 38: ...2 12 WiNG 5 6 Access Point System Reference Guide ...
Page 74: ...3 36 WiNG 5 6 Access Point System Reference Guide ...
Page 468: ...6 2 WiNG 5 6 Access Point System Reference Guide Figure 6 1 Configuration Wireless menu ...
Page 568: ...6 102 WiNG 5 6 Access Point System Reference Guide ...
Page 614: ...7 46 WiNG 5 6 Access Point System Reference Guide ...
Page 660: ...8 46 WiNG 5 6 Access Point System Reference Guide ...
Page 716: ...9 56 WiNG 5 6 Access Point System Reference Guide ...
Page 730: ...10 14 WiNG 5 6 Access Point System Reference Guide ...
Page 982: ...14 20 WiNG 5 6 Access Point System Reference Guide ...
Page 984: ...A 2 WiNG 5 6 Access Point System Reference Guide ...
Page 1046: ...B 62 WiNG 5 6 Access Point System Reference Guide ...
Page 1047: ......