5 - 364 WiNG 5.6 Access Point System Reference Guide
9. Select the
Path Method SNR
tab to configure the signal to noise ratio when selecting the path to the mesh point root.
Figure 5-246
Mesh Point Auto Channel Selection Path Method SNR screen
Priority Meshpoint
Configure the mesh point to be monitored for automatic channel scan. This is the mesh
point that given priority over other available mesh points. When configured, a mesh is
created with this mesh point. When not configured, a mesh point is automatically
selected.
Off Channel Duration
Configure the duration in the range of 20 - 250 milliseconds for the
Off Channel Duration
field. This is the duration that the scan dwells on each channel when performing an off
channel scan.
Off Channel Scan
Frequency
Configure the time duration in seconds between two consecutive Off Channel Scans. Set
a duration between 1 - 60 seconds.
Meshpoint Root - Sample
Count
Configure the number of scans to be performed for data collection before a mesh channel
is selected. Set a value between 1 - 10 scans.
Meshpoint Root - Channel
Hold Time
Configure the minimum duration to stay on a selected channel before the channel
conditions are reassessed for a possible channel change. Set a value between 0 - 1440
minutes. Set this value to ‘Zero’ (0) to prevent a automatic channel selection from
happening.
Summary of Contents for WiNG 5.6
Page 1: ...Motorola Solutions WiNG 5 6 ACCESS POINT SYSTEM REFERENCE GUIDE ...
Page 2: ......
Page 22: ...8 WiNG 5 6 Access Point System Reference Guide ...
Page 26: ...1 4 WiNG 5 6 Access Point System Reference Guide ...
Page 38: ...2 12 WiNG 5 6 Access Point System Reference Guide ...
Page 74: ...3 36 WiNG 5 6 Access Point System Reference Guide ...
Page 468: ...6 2 WiNG 5 6 Access Point System Reference Guide Figure 6 1 Configuration Wireless menu ...
Page 568: ...6 102 WiNG 5 6 Access Point System Reference Guide ...
Page 614: ...7 46 WiNG 5 6 Access Point System Reference Guide ...
Page 660: ...8 46 WiNG 5 6 Access Point System Reference Guide ...
Page 716: ...9 56 WiNG 5 6 Access Point System Reference Guide ...
Page 730: ...10 14 WiNG 5 6 Access Point System Reference Guide ...
Page 982: ...14 20 WiNG 5 6 Access Point System Reference Guide ...
Page 984: ...A 2 WiNG 5 6 Access Point System Reference Guide ...
Page 1046: ...B 62 WiNG 5 6 Access Point System Reference Guide ...
Page 1047: ......