Programming Model
http://www.motorola.com/computer/literature
3-19
3
Tick Timer 1 Counter
The Tick Timer 1 Counter is a 32-bit read/write register located at address
$FFF42008. When enabled, it increments every microsecond. Software
may read or write the counter at any time.
Tick Timer 2 Compare Register
The Tick Timer 2 Compare Register is a 32-bit register located at
$FFF4200C. The count value of Tick Timer 2 is compared to this register.
When they are equal, an interrupt is sent to the Local Bus interrupter and
the overflow counter is incremented. If the clear-on-compare mode is
enabled, the counter is also cleared. For periodic interrupts, the following
equation should be used to determine the compare register value for a
specific period.
compare register value = T (
µ
s)
When programming the tick timer for periodic interrupts, the counter
should be cleared to zero by software and then enabled. If the counter does
not initially start at zero, the time to the first interrupt may be longer or
shorter than expected. The rollover time for the counter is 71.6 minutes.
ADR/SIZ
$FFF42008 (32 bits)
BIT
31
. . .
0
NAME
Tick Timer 1 Counter
OPER
R/W
RESET
X
ADR/SIZ
$FFF4200C (32 bits)
BIT
31
. . .
0
NAME
Tick Timer 2 Compare Register
OPER
R/W
RESET
0 P
Summary of Contents for MVME1X7P
Page 16: ...xvi ...
Page 18: ...xviii ...
Page 20: ...xx ...
Page 26: ...xxvi ...
Page 90: ...1 64 Computer Group Literature Center Web Site Programming Issues 1 ...
Page 248: ...3 50 Computer Group Literature Center Web Site PCCchip2 3 ...
Page 286: ...4 38 Computer Group Literature Center Web Site MCECC Functions 4 ...
Page 288: ...A 2 Computer Group Literature Center Web Site Summary of Changes A ...
Page 316: ...Index IN 14 Computer Group Literature Center Web Site I N D E X ...