TABLE U: PROCEDURE FOR THE CORRECT
INSERTION OF THE ABS CONTROL UNIT
CONNECTOR
•
Place the connector on the opposite
side of the control unit and lower the
driving lever until the "click" that signals
the end of the stroke is heard.
TABLE U1: CORRECT ASSEMBLY
•
When the connector is fully inserted,
the distance between the connector
and the ABS control unit must be 7.5
mm (0.29 in).
TABLE U2: WRONG ASSEMBLY
•
If the initial position of the connector
and the pulling level is not as the one
previously shown, the connector will
not hook correctly and the distance
measured will be higher than approxi-
mately 12 mm (0.47 in). In this case,
repeat the connection operations.
Back side
TABLE A
1. Clamp.
2. Plug socket.
3. Fit the hood carefully.
Norge GT 8v
Electrical system
ELE SYS - 91