and the Marelli control unit connector: If not OK, restore. If OK, check continuity between
the BLUE connector PIN 22 and PIN 32 and restore the cable harness.
ELECTRICAL ERRORS
Right lambda sensor P0136
- Shorted to positive.
Error cause
•
Excessive voltage (battery voltage) has been detected at PINS 21 and 31 of the BLUE
connector.
Troubleshooting
•
shorted to positive: with key set to ON, disconnect the sensor connector and measure PIN
1 voltage on the cable harness side (purple cable): if there is voltage (5 or 12 V), restore the
cable harness; it there is no voltage, measure voltage at PIN 2, cable harness side, (brown
cable) and if there is voltage, restore the cable harness; if there is no voltage, replace the
lambda sensor.
Right lambda sensor heating P0141
- shorted to positive / open circuit, shorted to negative.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 1 of the BLUE connector.
•
If the circuit is open, shorted to negative: voltage equal to zero has been detected at PIN 1
of the BLUE connector.
Troubleshooting
•
shorted to positive: disconnect the probe connector and check the sensor correct resistance:
replace the sensor if not OK; if it is OK, restore the cable harness.
•
circuit is open, shorted to negative: check the continuity from probe connector (PIN 3 and
4) towards the probe: if not OK, replace the probe; if it is correct, check the sensor connector
and the Marelli control unit connector. If not OK, restore. If OK, and with key set to ON and
sensor connector disconnected, check if there is battery voltage at PIN 4: if not ok, check
the red/black cable (cable harness side) between the probe connector and the auxiliary
injection relay (No. 33 in the wiring diagram, located under the saddle, left rear relay in the
relay group attached to the fall sensor; CHECK, however, the identification of the relay with
the colour of the cables). If there are also coil and injector errors, check the relay itself and
its excitation and power line; if there is voltage at PIN 4, check the black/white cable ground
insulation, cable harness side (PIN 3): if it is not OK, restore the cable harness. If OK, check
continuity of the white/black cable, cable harness side (between PIN 3 of the sensor con-
nector and PIN 1 of the BLUE connector) and restore the cable harness.
LOGIC ERRORS
Lambda sensor P0140 -
voltage without variation.
Error cause
Norge GT 8v
Electrical system
ELE SYS - 115