B-10 MANUAL OPERATION
<To restart operation>
1)
Close the front door.
2)
Pull out all the EMERGENCY STOP buttons to reset
the emergency stop state.
If the machine has more than one EMERGENCY
STOP button, it is necessary to pull out all the
EMERGENCY STOP buttons from the pushed
and locked position to reset the emergency state.
3)
Press the NC power switch
(ON).
If the NC power switch
(ON) is pressed while
the door is open, the following message is
displayed.
"EX4002 OPEN THE DOOR THEN CLOSE"
In this case, close the front door.
When the machine is restored to the operation
ready condition, the status indicator
[MRDY]
is lit.
An alarm number is displayed on the screen while
the machine is in alarm status.
If the alarm cannot be cleared, contact Mori Seiki.
4)
Carry out the zero return operation.
NOTE
ON
OFF
NOTE
X
Z
MRDY
TRCL
CHCL
ERR
NOTE
MEM
MDI
TAPE
EDIT
H
JOG
RPD
ZRN