A-46 OPERATION PANELS
5-14
Turret Switches
The turret switches are used to index the turret manually.
1.
Switch operation is impossible with the
PANEL key-switch placed in the
(OFF)
position.
2.
Close the front door before pressing the
turret indexing switch
.
For the condition for turret indexing, refer to page B-36 (8).
Switch
Function
The display unit shows the presently indexed turret number.
When indexing the turret manually, set the station number to which the
turret is to be indexed.
The turret station setting switches are used to set the target turret station
number where the turret is to be indexed manually.
1.
When the turret station setting switch
(increase) is pressed
and released, the target station number is increased by one.
2.
When the turret station setting switch
(decrease) is pressed
and released, the target station number is decreased by one.
1.
Selection of turret 1 and turret 2 is made by pressing the
head selection switches
(head 1) and
(head 2).
2.
The set target station number blinks in the display unit.
The turret indexing switch is used to index the turret head manually.
After setting the target station number with the turret station setting
switches
(increase) and
(decrease), press this switch while the
set number is blinking.
WARNING
Be aware that the turret head will start rotating if the turret indexing switch
is pressed by mistake while the conditions for turret indexing are
satisfied and a manual mode is selected. If this switch is pressed
carelessly the turret will start rotating unexpectedly and this could cause
accidents involving serious injuries or damage to the machine.
NOTE
NOTE
1
2