DOOR INTERLOCK FUNCTION P-27
5-2-1
Opening/Closing the Door (Automatic Door Type)
The door can be opened or closed either by executing the door open/close M code (M85/M86) or
operating the AUTOMATIC DOOR OPEN/CLOSE switch.
<Using the door open/close M codes>
When opening/closing the automatic door in automatic operation (includes MDI operation),
execute the M codes (M85/M86).
<Using the AUTOMATIC DOOR OPEN/CLOSE switch>
The AUTOMATIC DOOR OPEN/CLOSE switch, provided
on the option panel, is used to open/close the automatic
door manually.
The AUTOMATIC DOOR OPEN/CLOSE switch is
not operative when the PANEL key-switch is
placed in the
(OFF) position.
Door
Command
Function
Unlock
Door open
(M85)
When this command is executed, the door is automatically
unlocked and opened.
Lock
Door close
(M86)
When this command is executed, the door is closed and after
the completion of door closing, it is locked automatically.
Switch
Function
When this switch is pressed, the door is unlocked and opened.
When this switch is pressed, the door is closed and after the completion of
door closing, the door is locked.
AUTOMATIC
DOOR OPEN
AUTOMATIC
DOOR CLOSE
NOTE
AUTOMATIC
DOOR OPEN
AUTOMATIC
DOOR CLOSE