Operators Guide
DigiBook 450
92
rel. 2.00-B
Verify the presence of glue in the tank.
Verify that the glue in the tank is not cured.
Verify that the tank valve is open.
Verify the position of the internal lateral jaw: it must be 0.10 tenths back from the edge
of the clamp.
Verify the head height: if it comes out a little glue lower the head and increase the air
pressure of the glue group, if it comes out to much glue raise the head and lower the air
pressure of the glue
Verify that the glue is not deteriorate
14.7
NIPPING STATION
Press so much: lower the air pressure of the press group or the spine height.
Round spine: increase the press height.
Edge pinched: contact technical support.
Not uniform spine: contact technical support.