Operators Guide
DigiBook 450
19
rel. 2.00-B
2.1.1
E
LECTRICAL
S
PECIFICATION
Electrical power 400 V ±5%, 50 Hz, 3 ph + N + PE
Power of the machine
Protection fuses on the power network are duties of
the customer
Distribution cabinet, customer side
16 A
Differential protection class A 300mA
2.1.2
P
NEUMATICS
S
PECIFICATION
Supply pressure
The pneumatic system of the user must ensure, in the inlet connection of the compressed air in the perfect
binder, the following values:
Min.: 101.5psi (7 bar)
Must guarantee an air consumption of 12.3
ft
3
/min (350 l/min)
air quality:
Class 3
Pneumatic Characteristics of the machine
Compressed air consumption
7.06 ft/min (220 l/min)
Calibration of input gauge
87 psi (6 bar)
Min. working pressure
79.7 psi. (5.5 bar) If the pressure value falls below this value the machine enter in an “alarm” condition
Diameter of air inlet
0.39in (10mm)
The 0.39in diameter hose for the connection to the compressor is not provided together with the machine.
It is suggested the use of a compressor equipped with the automatic condensate drain, to avoid verify
weekly if there is some water inside the compressor.
It is suggested to use a silenced compressor, if the compressor is located inside the working plant.
Air quality provided to the Perfect Binder
CLASS 3, DIN ISO 8573-1
Durst: 5 micron - 5 mg/m3
Water: -20°C (-4F)
- 0,88 g/m3
Oil: 1 mg/m3