Operators Guide
DigiBook 450
76
rel. 2.00-B
12.2
SWITCHING ON THE MACHINE
01
Switch on the machine using the main switch.
Move the switch to ON position
02
Verify that the pressure indicated on manometer is cor-
rect. MIN 6 bar
03
Open the valve on premelter.
The valve with the lever on vertical position means open.
04
Verify the chosen temperatures
05
Make a general reset, pressing START button
06
Position the axes, pressing START button
07
Press the button
Launch the procedure, the machine do a series of cycles
opening and closing the glue valve.
At a later stage, follow meticulously the procedure be-
low.