A.2.4
G395-016 to G395-070, liquid cooling
Designation
Technical data
G395-016
G395-020
G395-024
G395-032
G395-053
G395-070
Output, motor side
1)
Voltage
2)
3-phase U
Mains
Rated current, effective (l
n
)
16 A
20 A
24 A
32 A
53 A
70 A
Peak current
See A.1.4
See A.1.5
Rotating field frequency
0 ... 400 Hz
Switching frequency of the power stage
4, 8, 12, 16 kHz
Input, mains side
Mains voltage
(3 x 230 V/ 3 x 400 V/ 3 x 460 V/ 3 x 480 V) ±10 %
Device connected load
1)
(with mains choke)
12 kVA
15 kVA
18.2 kVA
24.2 kVA
36.7 kVA
48.5 kVA
Current
1)
(with mains choke)
17.3 A
21.6 A
26.2 A
34.9 A
53 A
70 A
Asymmetry of mains voltage
±3 % maximum
Frequency
50/60 Hz ±10 %
Power dissipation at I
N
1)
330 W
400 W
475 W
515 W
690 W
930 W
DC link
Capacitance
1230 µF
2000 µF
430 µF
900 µF
Brake chopper switch-on threshold
650 V DC
1)
820 V DC
1)
Data referred to mains voltage 3 x 400 V
eff
and switching frequency of the power stage 8 kHz
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2/xx4)!
4)
Cooling performance adequate also with optional internal braking resistor
Table A.12 Technical data, G395-016 to G395-070, liquid cooling
Designation
Technical data
G395-016
G395-020
G395-024
G395-032
G395-053
G395-070
Minimum ohmic resistance of an
externally installed braking resistor
20
Ω
12
Ω
10
Ω
3)
Brake chopper peak power with external
braking resistor
21 kW
35 kW
67 kW
Optional:
Internal braking resistor
-
20 Ω
10 Ω
Brake chopper continuous power
with internal braking resistor
-
675 W
1350 W
Brake chopper peak power
with internal braking resistor
-
34 kW
67 kW
Chiller data
Coolant pressure
(rated value / maximum value)
1 / 2 bar
Coolant flow rate
4)
(rated value / maximum value)
3 / 4 l per min
8 / 11 l per min
Feed coolant temperature
The coolant temperature can be b5 °C (+41 °F) and +40 °C
(+104 °F). However, the coolant temperature should not be more than
10 °K below the ambient temperature to prevent condensation on the heat
sink.
1)
Data referred to mains voltage 3 x 400 V
eff
and switching frequency of the power stage 8 kHz
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2/xx4)!
4)
Cooling performance adequate also with optional internal braking resistor
Table A.12 Technical data, G395-016 to G395-070, liquid cooling
Summary of Contents for G305-170
Page 1: ...moog AC AC Servo Drive Single axis System 4 A to 450 A MSD Servo Drive Operation Manual...
Page 6: ...6 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 82: ...82 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 88: ...88 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 89: ...89 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...