38
Electrical installation
MSD Single-Axis System Operation Manual AC-AC Servo Drive
ID no.: CA65642-001 06/2018
moog
Des.
Term.
Specification
Electrical isolation
Digital outputs
REL
REL
ISDSH
ISD06
ISD05
ISD04
ISD03
ISD02
ISD01
ISD00
+24V
DGND
RSH
RSH
ENPO
OSD02
OSD01
OSD00
ISA1-
ISA1+
ISA0-
ISA0+
+24V
DGND
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
X4
OSD00
OSD01
OSD02
X4/7
X4/8
X4/9
•
No irreparable damage in the event of a short circuit
(+24 V -> GND), however, device may briefly shut down.
•
I
max
= 50 mA, PLC-compatible
•
Terminal scan cycle in = 1 ms
•
High-side driver
Yes
STO "Safe Torque Off" (*)
ISDSH
(STO)
X4/22
•
Input "Request STO" = low level
•
OSSD support (from hardware version 2)
•
Switching level low/high: ≤4.8 V / ≥18 V
•
U
IN max
= +24 V DC +20 %
•
I
IN
at +24 V DC = typ. 3 mA
Yes
RSH
RSH
X4/11
X4/12
Diagnostics STO, both shut-off channels
active, one NO contact with automatically
resetting circuit breaker (polyswitch)
•
25 V / 200 mA AC, cos
ϕ
= 1
•
30 V / 200 mA DC, cos
ϕ
= 1
X4/12
X4/11
Yes
Relay output
REL
X4/23
X4/24
Relay, 1 NO contact
•
25 V / 1.0 A AC, cos
ϕ
= 1
•
30 V / 1.0 A DC, cos
ϕ
= 1
•
Switching delay approx. 10 ms
•
Cycle time 1 ms
X4/23
X4/24
Auxiliary voltage
+24 V
X4/2
X4/14
•
Auxiliary voltage for supplying the digital inputs
•
U
H
= U
V
-∆U (∆U typically approx. 1.2 V), no irreparable
damage in the event of a short circuit (+24 V -> GND), but
device may briefly shut down.
•
I
max
= 80 mA (per pin) with self-resetting circuit breaker
(polyswitch)
Yes
Digital ground
DGND
X4/1
X4/13
Reference ground for 24 V, I
max
= 80 mA (per pin), hardware
versions 0..1 with self-resetting circuit breaker (polyswitch)
Yes
(*) STO certification only applies for Size 1 to Size 6A
Table 4.10 Specification of the control connections X4
NOTE:
If excessively high currents flow via the earth terminals, high-impedance
isolation from the device ground is possible. In some circumstances this can
result in the malfunction of the drive. To prevent this situation arising, avoid
currents circulating in the wiring.
4.9.2
Brake driver
On Size 1 to Size 4 the connector X13 is intended to be used to connect a motor brake.
Des.
Term.
Specification
Connection
OSD03
GND
X13/1
X13/2
•
Short circuit proof
•
Power is supplied via the control supply U
V
on
X9/X10.
•
U
BR
= U
V
-∆U` (∆U` typically approx. 1.4 V)
•
For operating a motor holding brake up to
I
BR
= 2.0 A maximum, for brakes with a higher
current requirement a relay must be connected
in between.
•
Overcurrent causes shutdown
•
Can also be used as configurable digital output.
• Configurable cable break monitoring <500 mA
in state "1" (up to the relay)
X13
M
Brake (+)
Brake (-)
OSD03 1
GND 2
Table 4.11 Specification of the terminal connections X13 (Size 1 to Size 4)
On Size 5 to Size 6A the connector X20 is intended to be used to connect a motor
brake.
Summary of Contents for G305-170
Page 1: ...moog AC AC Servo Drive Single axis System 4 A to 450 A MSD Servo Drive Operation Manual...
Page 6: ...6 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 82: ...82 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 88: ...88 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 89: ...89 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...