36
Electrical installation
MSD Single-Axis System Operation Manual AC-AC Servo Drive
ID no.: CA65642-001 06/2018
moog
4.8.6
Connection diagram, precharging (only Size 7)
Designation
Specification
G395-250
G395-325
G395-450
Fuses 2, slow blow
For values see Table 4.10
Mains filter (optional)
300 A
400 A
500 A
Mains choke (U
k
= 2 %)
250 A
325 A
450 A
K1
(e.g. Siemens 3RT10 65-
6AP36)
(e.g. Siemens 3RT10 75-
6AP36)
(e.g. Siemens 3RT10
76-6AP36)
K2
12 A / 5.5 kW / 24 V (e.g. Siemens 3RT10 17-1AB01)
K3
7 A / 3 kW / 24 V (e.g. Siemens 3RT10 15-1AB01)
Table 4.9 Example data for Figure 4.17
Wire the precharging circuit according to the standards using short circuit proof cables.
The connection ratings for the internal relay for the terminals X44/3, 4 are
U
max
= 30 V DC, I
max
= 6 A. Use an auxiliary contactor K3.
Control process
y
Precharging the DC link
Switch S1 "Mains supply On" is switched on. The precharging contactor K2 closes and the DC link is
precharged via internal precharging resistors on terminal X45. The main contactor K1 remains open
initially.
y
Precharging completed
At a defined DC link voltage the contact on the internal relay on terminal X44/3,4 is closed. The auxiliary
contactor K3 closes and switches on the main contactor K1. The precharging contactor K2 is opened via
an auxiliary contact (normally closed contact) on K1. The MSD Servo Drive changes to ready to operate.
y
Switching off
Via switch S1 "Mains supply Off" the servo drive is completely disconnected from the mains.
L1
L2
L3
Mains choke
Precharge circuit
short cicuit proof
Mains
Precharge
Control
supply
Supply and
triggering of the
motor brake
K2
K1
Fuses 1
Main conductor
N
PE
Mains filter
(optional)
Fuses 2
K2
K1
K3
24
V
24 V
S1
GND
GND
GND
24
V
OSD03
GND
G395-250
G305-325
G395-450
internal
relay
RB
− +
L1 L2 L3 PE
W
V
U
PE
ZK- ZK+
X11
L1 L2 L3
X45
X12
Braking
resistor
1 2
3
4
5
6
7
X44
K1
K3
Figure 4.17 Connection example, precharging, control/mains supply 3 x 230/400/460/480 V
for Size 7
CAUTION! Shutdown of the precharging!
In order to protect the servo drive against thermal overload, it must be ensured that the
precharging of the DC link is not set for more than
2 minutes
without the main contactor
being active. The precharging of the DC link is not designed for high power consumption during
operation.
Failure to do so may destroy the device!
Summary of Contents for G305-170
Page 1: ...moog AC AC Servo Drive Single axis System 4 A to 450 A MSD Servo Drive Operation Manual...
Page 6: ...6 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 82: ...82 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 88: ...88 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 89: ...89 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...