Commissioning
5.4.4
Ethernet IP address menu (IP)
An Ethernet TCP/IP port is available as a service and diagnostics interface. The IP
address is set in the factory to 192.168.39.5. It can be changed using the PC software
Moog
D
rive
A
DministrAtor
5
or via the display.
Menu level
Parameter
Value
range
Meaning
Explanation
1
2
IP
Iu
b0
00..FF
IP address
update byte 0
Setting for byte 0 of the IP address in
hexadecimal format
(e.g. "05" in 192.168.39.
5
)
b1
00..FF
IP address
update byte 1
Setting for byte 1 of the IP address in
hexadecimal format
(e.g. "27" for 192.168.
39
.5)
b2
00..FF
IP address
update byte 2
Setting for byte 2 of the IP address in
hexadecimal format
(e.g. "A8" for 192.
168
.39.5)
b3
00..FF
IP address
update byte 3
Setting for byte 3 of the IP address in
hexadecimal format
(e.g. "C0" at
192
.168.39.5)
Ir
-
-
IP reset to
factory setting
Reset IP address to factory setting
(192.168.39.5)
Su
b0
00..FF
Subnet mask
update byte 0
Setting for byte 0 of the subnet mask in
hexadecimal format
(e.g. "00" in 255.255.255.
0
)
b1
00..FF
Subnet mask
update byte 1
Setting for byte 1 of the subnet mask in
hexadecimal format
(e.g. "FF" in 255.255.
255
.0)
b2
00..FF
Subnet mask
update byte 2
Setting for byte 2 of the subnet mask in
hexadecimal format
(e.g. "FF" in 255.
255
.255.0)
b3
00..FF
Subnet mask
update byte 3
Setting for byte 3 of the subnet mask in
hexadecimal format
(e.g. "FF" in
255
.255.255.0)
Sr
-
-
Subnet mask
reset to
factory setting
Reset subnet mask to factory setting
(255.255.255.0)
Table 5.7 IP address menu
Example configuration of the subnet mask
In this example the subnet mask is changed from 255.255.255.0 to 122.255.255.0.
T1
T2
Tx
Tx
back
back
back
several actuations
of buttonTx (X = 1, 2)
until the desired menu
appears in the display
single actuation
of button Tx (X = 1, 2)
simultaneous actuation
of both buttons T1 and T2
Actuation of
any button
accept
>5 s
>5 s
<5 s
T2
<5 s
T1 T2
T1 T2
T1 T2
back
T1 T2
back
T1 T2
T1 T2
T1 T2
T1 T2
Value NOT
saved
Value
saved
T1
T2
T1
T1
back
T1 T2
T2
Figure 5.3 Example configuration of the subnet mask
Summary of Contents for G305-170
Page 1: ...moog AC AC Servo Drive Single axis System 4 A to 450 A MSD Servo Drive Operation Manual...
Page 6: ...6 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 82: ...82 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 88: ...88 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 89: ...89 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...