A.7 Hydrological data for the liquid cooling
CAUTION!
Damage to the device due to condensation on the cooling plate
•
Carelessness can cause condensation on the cooling plate and as a
consequence irreparable damage to the device!
The temperature of the cooling plate is not allowed to be more than +10 °C (+50 °F) below the
ambient temperature.
NOTE:
Adequate heating of the water chiller is to be provided by the customer.
The coolant is to be approved by Moog.
Requirements
Limits
Coolant quality
Recommended: tap water + corrosion inhibitor (e.g. ethylene glycol)
Not allowed are: chloride ions (Cl- >100 ppm), calcium carbonate (CaCO3 >160 ppm)
Soiling
The coolant must be as pure as possible to ensure the channels are not clogged. With
a suspended matter concentration of more than 15 mg/dm³, continuous purification is
recommended.
Coolant temperature
The coolant temperature can be b5 °C and +40 °C (+41 °F and +104 °F).
However, the coolant temperature should not be more than 10 °K below the ambient
temperature to prevent condensation on the heat sink.
Cooler material
Aluminium
Table A.22 Requirements, liquid cooling
Size
Size 3
Size 4
Size 5
Size 6A
Size 7
Coolant pressure
(rated value / maximum value)
1 bar / 2 bar
Coolant flow rate
(rated value approx. /
maximum value approx.)
3 l per min /
4 l per min
8 l per min /
11 l per min
11 l per min /
13 l per min
12 l per min /
14 l per min
Table A.23 Hydrological data for the liquid cooling
A.8 Monitoring of the heat sink
temperature
If the maximum permissible cooling temperature is exceeded, the servo drives shut
down with an overtemperature error.
Size
Size 3
Size 4
Size 5
Size 6A
Size 7
Device
G395-016
G395-020
G395-024
G395-032
G395-045
G395-060
G395-072
G395-090
G395-110
G395-143
G395-170
G395-250
G395-325
G395-450
Shutdown of the device at a
cooling temperature of
+65 °C (+149 °F)
+90 °C (+194 °F)
Should, for devices with liquid cooling, the coolant flow rate collapse or not become
established, the power stage may overheat. For this reason the servo drive is equipped
with dynamic monitoring of the heat sink temperature that shuts down the servo drive if
there is an excessively high temperature gradient.
A.9 UL certification
The description of all measures to maintain UL certification is to be found in the
document "UL-Certification" (ID No: CC36842-001).
Summary of Contents for G305-170
Page 1: ...moog AC AC Servo Drive Single axis System 4 A to 450 A MSD Servo Drive Operation Manual...
Page 6: ...6 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 82: ...82 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 88: ...88 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Page 89: ...89 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...