17.4.3 Read Switch Program from ETC (upload)
If once it is needed to save a switch program from an ETC, or to copy it to an other ETC,
you are able to read (upload) the current program. After confirming the security check,
the ETC starts sending the switch program over the RS 232 interface. The used
communication parameters are 19'000 Bit/s, 1 Stop Bit, no parity. To read (upload) the
program file, the SwitchEditor software or a simple terminal program with capture
function can be used. The received data should be saved as a *.PRG file. By means of
the ETCW software, the file can be downloaded to another ETC.
MENU
File
manager
Switch
program
Read
program
Notice:
The RS 232 – communication parameters are
not
reset to the previous
values after the upload is finished.
17.5 Time zone table
A new season table (time zone table) can be loaded on the ETC through the interface.
For further information concerning the season table, see Chapter 5 and Annexe C.
17.5.1 Download
Season Table from a PC
The ETC changes into download mode and waits for a new season table through the
interface.
MENU
File
manager
Season
table
Load season table
Notice:
The time zone entries defined by the user are placed within the season table
from position 80 on.
17.6 Default
Configuration
The default configuration (factory settings) will be loaded after the confirmation prompt.
With this function the switch program memory and the switch program in RAM are
deleted too.
MENU
File
manager
Default
config.
After the selection, the execution has to be confirmed.
A summary of the default configuration (factory settings) are listed in appendix B.
17.7 User
Configuration
The current
ETC configuration and the switch program can be saved in the non-volatile
flash memory and loaded again from this memory. The settings are thus retained even
after a software update.