13.2.4 Communication
Parameters
Defines the communication parameters for the data transmission.
...
Port COM X [RSXXX]
Configuration
Baudrate:
Parity:
Data
Bit:
Stop
Bit:
Baudrate:
300, 600, 1200, 2400, 4800, 9600, 19200 Bit/s
Parity:
even, odd, none
Data bit:
7,
8
Stop bit:
1, 2
Notice:
CAS communication is only possible with one of the following baudrate
settings: 1200, 2400, 4800, 9600 or 19200 Bit/s. CAN communication is only
possible with the settings 19200/8/none/1.
13.2.5 Telegram
Format
The selected telegram format (menu "Configuration") is output every second, when
interface mode is set to telegram output ("Tele."). The following telegram formats are
available (definition in annexe F):
IF482 17
characters
DIEM 24
characters
SINEC 32
characters
H7001 18
characters
BUS485
20 characters (only for RS 422 interface, hexadecimal-format)
...
Port COM X [RSXXX]
Configuration
Telegram: IF482
13.2.6 Telegram Send Offset
The output process of all telegram formats starts at the beginning of each second. As
the second designated in the telegram is 0, the content of the telegram is valid at the
beginning of the telegram. If the content of the telegram should be valid at the end of the
telegram, a send offset has to be set. (The time designated in the telegram does not
change thereby, the second is still 0).
...
Port COM X [RSXXX]
Configuration
Send offset: 0020
The unit of the send offset are milliseconds. The value can be set in steps of 5
milliseconds (with automatic rounding up and rounding down). The maximum send offset
value is 700 ms. The following table can be used to determine the transmission duration
and the corresponding send offset for the selected telegram format: