© MOBATIME
46 / 96
800337.22
13.2 Parameters / Operating modes
13.2.1 Line Time and Date
The displayed time and date cannot be changed and is based on the selected time zone
of this line.
MENU
Serial
comm.
Port COM X [RSXXX]
Time:
Date:
13.2.2 Line
Mode
Selection of the interface mode.
...
Port COM X [RSXXX]
Mode:
Off
Synchronisation Telegram
Output
CAS-
Communication
CAN-
Communication
Remote
Download
ETC 12(R)
ETC 14(R)
ETC 24(R)
In start-up state all interfaces are switched off, which means that no function is selected.
The table above shows the functions that can be selected by the user.
Synchronisation
There are several ways possible to synchronise the ETC using a serial interface (refer
to chapter 10). When an interface is chosen for synchronising the clock in menu
"Synchronisation" the text "Synch." appears in the "Serial communication" menu. Only
one interface can be selected for synchronisation at the same time.
Telegram Output
This function forces the master clock to output the serial telegram format, selected in the
submenu "Configuration", every second (definition in annexe F). The text "Tele." appears
in the display.
CAS Communication
When selecting the function CAS-Communication, the ETC is synchronised by the CAS
module of a Master Time Center MTC and is working as a sub-master clock. Further
the ETC will report alarm messages to the MTC. Some parameters such as the system
address must be set in menu "Synchronisation". The text "CAS" appears in the display.