Option IRIG-B: IF 488 Configuration
Generates a time synchronous DCF-FSK, or IRIG-B,or IRIG-E code telegram for automatic
time transfer to external time systems from the MOBALine-Code of the DTS 4801. With the
integrated DIP switch, 7 different time code formats can be selected. The alarm contact is
monitored by the DTS 4801.
(DTS 4801 IRIG-B: Art. No: 203495)
Output code format:
With DIP switch 1 to 4 "MODE" is configurable:
Code
1 2 3 4 Code
definition
according to data sheet
DCF-FSK:
on on on on 112
071
IRIG-B
Standard:
off on on on 112
072
IRIG-B
Standard
on off on on 112
073
12 Std.-Format
IRIG-B
"DIEM"
off off on on 112
074
AFNOR
A:
on on off on 112
075
AFNOR
C:
off on off on 112
076
IRIG-E
"DIEM":
on off off on 112
077
Technical specifications:
Input:
MOBALine
Output:
600 Ohms galvanically separated:
DCF-FSK:
Pulse 1kHz / pause 1,25 kHz
2Vp-p
IRIG-B:
Modulation 1 kHz
2Vp-p / 0,66Vp-p
IRIG-E:
Modulation 100 Hz
2Vp-p / 0,66Vp-p