![Mobatime DTS 4801.masterclock Instruction Manual Download Page 100](http://html1.mh-extra.com/html/mobatime/dts-4801-masterclock/dts-4801-masterclock_instruction-manual_1814681100.webp)
© MOBATIME
100 / 120
800652.11
22
Wrong time zone DCF in
Check time zone settings (time source).
23
Syn only diff too large
Check synchronization and source
24
No mail server
Check e-mail configuration.
Observe file mailerror.txt in /ram/ for error correction.
25
SNMP not working
Check SNMP and trap configuration.
26
Error bit26
Not used
27
Error bit27
Not used
28
Linie 2 current too high
Check MOBALine / Impulse line / DCF active line.
Alarm disappears only, if alarm is removed.
(Only active with DTS 4802)
29
Line 2 wrong time zone
Check time zone setting in (MOBALine / Impulse line)
(Only active with DTS 4802)
30
Error bit30
Not used
31
Error bit31
Not used
32-62
Error device 1-31
RS485 line: Device error
for detailed error description see
chapter 6.5.8.
(Only active with DTS 4801)