9.3.5 Alive
Notification [dts480xAlive]
Sent out in a configurable interval.
This
Notification
is always sent out, as soon as SNMP and the alarm traps are
activated and a destination address is configured.
The
Notification
sent out contains the following data:
Field Type
Size
Description
Example
dts480xSysStatus
Unsigned Int
4 Bytes Contains the internal
system status
66309
dts480xSysAlarms
Byte Array
8 Bytes 64 Bit Alarm flags
1.Byte Bit 0..7
2.Byte Bit 8..15
::
8.Byte Bit 56..63
FFF870FF.FFFFFFFF
¦ ¦ ¦
¦ ¦ 5.Byte
¦ 2.Byte
1.Byte
9.3.6 Alarm
Notification
[dts480xAlarm]
Sent out if alarm status changes, i.e.
Notification
is sent out when an alarm flag is set
or deleted.
This
Notification
is always sent out, as soon as SNMP and the alarm traps are
activated and a destination address is configured.
The
Notification
sent out contains the following data:
Field Type
Size
Description
Example
dts480xTrapAlMsgErrorNr
Byte
1 Bytes No. of the alarm bit (0..63)
8
dts480xTrapAlMsgErrorState Byte 1
Bytes
0 = alarm bit was deleted
1 = alarm bit was set
1
dts480xTrapAlMsgErrorTime Unsigned
Int
4 Bytes PC-time in seconds since
01.01.1970 00:00:00
946684805
dts480xTrapAlMsgErrorText Text
59 Bytes Error text
Line current too
high