3 -
12
3.
SYSTEM CONFIGURATION
S
p
eci
al
f
unc
tion
mo
dul
e
D/A
converter
module
A68DAV
0 to
10V, analog output, 8 channels.
32 (special 32 points)
0.15
0.5
A68DAI-S1
0 to 20mA, analog output, 8 channels.
32 (special 32 points)
0.15
0.4
A62DA
4 to 20mA/0 to
10V
Analog output 12 bits, 2 channels
32 (special 32 points)
0.6
0.35
A62DA-S1
4 to 20mA/0 to
10V Analog output,
2 channels
A616DAI
4 to 20mA. Resolution: 1/4000
Analog output, 16 channels
32 (special 32 points)
0.3
–
15VDC (A68P)
is
required.
A616DAV
0 to
10 V/0 to
5 V. Resolution: 1/4000
Analog output, 16 channels
32 (special 32 points)
0.38
–
15VDC (A68P)
is
required.
Memory
card,
Centronics
interface
module
AD59
32k byte-memory battery backup
Can be connected to printer conforming to
Centronics standards
32 (special 32 points)
0.3
–
AD59-S1
0.32
0.35A when
connected to
AD59MEF.
Voice output
module
A11VC
Messages can be recorded and played back on
a maximum of 60 channels.
The following recording times can be selected
for each channel: 1 second, 2 seconds,
4 seconds, 8 seconds.
The total recording time is 64 seconds
16 (special 16 points)
0.6
0.38
Network
module
AJ71QLP21
For MELSECNET/10 optical loop networks
(compatible with SI cable)
32 (special 32 points)
0.65
–
• For Use with
QnACPU
Only
• Maximum 4
modules can
be used for
one CPU
module.
(Refer to
Section 3.3.2 )
AJ71QLP21G
For MELSECNET/10 optical loop network
(compatible with GI cable)
AJ71QLP21S
For MELSECNET/10 optical loop networks.
Network backup by external power supply
32 (special 32 points)
0.65
0.2
AJ71QBR11
For MELSECNET/10 coaxial bus networks
32 (special 32 points)
0.8
–
AJ71QLR21
For MELSECNET/10 coaxial loop network
1.14
AJ72QLP25
For MELSECNET/10 optical loop network
remote I/O stations (compatible with SI cable)
–
0.8
–
AJ72QLP25G
For MELSECNET/10 optical loop network
remote I/O station (compatible with GI cable)
AJ72QBR15
For MELSECNET/10 coaxial bus network
remote I/O stations
–
0.9
–
AJ72QLR25
For MELSECNET/10 coaxial loop network
remote I/O station
1.3
Product Name
Model Name
Description
Number of Occupied
Points (points)
[I/O Allocation
Module Type]
Current Consumption
Remark
5VDC(A) 24VDC(A)
+0.53A
-0.125A
+0.2A
-0.17A
Summary of Contents for Q2ACPU
Page 1: ......
Page 2: ......
Page 221: ...12 12 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Page 222: ...12 13 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Page 237: ...12 28 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU MEMO ...
Page 271: ...16 13 16 POWER SUPPLY MODULE 4 Names and description of parts of the A66P ...
Page 343: ...21 21 13 MAINTENANCE AND INSPECTION 21 4 2 Replacement of the fuse for an output module ...
Page 357: ...22 12 22 TROUBLESHOOTING ...
Page 359: ...22 14 22 TROUBLESHOOTING MEMO ...
Page 429: ...App 32 APPENDICES Trigonometric function Classification Symbol Description ...
Page 537: ...App 140 APPENDICES REMARK 1 Message 1 An error code is displayed in 2 Alert 1 3 Alert 2 ...
Page 539: ...App 142 APPENDICES 2 Q2ACPU Q2ACPU S1 modules Unit mm inch ...
Page 541: ...App 144 APPENDICES 2 A66P power supply module Unit mm inch ...
Page 543: ...App 146 APPENDICES 3 A35B base unit 4 A38B A38HB A38HBEU base unit Unit mm inch Unit mm inch ...
Page 567: ...MEMO ...
Page 569: ......
Page 570: ......