20 -
7
20. EMC AND LOW VOLTAGE DIRECTIVES
(b) When connecting a cable longer than 2m (6.56ft.), but not exceeding 10m
(32.81ft.)
• Ground the shield section of the external wiring cable with a cable clamp.
(Ground the shield at the closest location to the AD75 external wiring
connector.)
• Install a ferrite core.
• Connect the external wiring cable to a drive unit or an external device in the
shortest distance.
(c) Models and required quantities of the ferrite core and cable clamp
• Cable clamp
• Ferrite core
• Required quantity
Model:
AD75CK (Manufactured by Mitsubishi Electric)
Model:
ZCAT3035-1330 (TDK ferrite core)
Contact: TDK Corporation
Cable length
Optional part
Required quantity
1 axis
2 axes
3 axes
2m (6.56ft.) or less
AD75CK
1
1
1
2m (6.6ft.) to 10m
(32.8ft.)
AD75CK
1
1
1
ZCAT3035-1330
1
2
3
Power supply
module
CPU module
AD
75
External wiring connector
Cable clamp
External wiring cable (within 2m (6.56ft.))
Drive unit
Ferrite core
Summary of Contents for Q2ACPU
Page 1: ......
Page 2: ......
Page 221: ...12 12 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Page 222: ...12 13 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Page 237: ...12 28 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU MEMO ...
Page 271: ...16 13 16 POWER SUPPLY MODULE 4 Names and description of parts of the A66P ...
Page 343: ...21 21 13 MAINTENANCE AND INSPECTION 21 4 2 Replacement of the fuse for an output module ...
Page 357: ...22 12 22 TROUBLESHOOTING ...
Page 359: ...22 14 22 TROUBLESHOOTING MEMO ...
Page 429: ...App 32 APPENDICES Trigonometric function Classification Symbol Description ...
Page 537: ...App 140 APPENDICES REMARK 1 Message 1 An error code is displayed in 2 Alert 1 3 Alert 2 ...
Page 539: ...App 142 APPENDICES 2 Q2ACPU Q2ACPU S1 modules Unit mm inch ...
Page 541: ...App 144 APPENDICES 2 A66P power supply module Unit mm inch ...
Page 543: ...App 146 APPENDICES 3 A35B base unit 4 A38B A38HB A38HBEU base unit Unit mm inch Unit mm inch ...
Page 567: ...MEMO ...
Page 569: ......
Page 570: ......