FX-TRN-BEG-E
D: Beginner Challenge 4
B-39
4.2.3
Control Objective
Have the flashing lights turn ON when a person or car is detected.
Use the basic instructions and timers previously studied.
4.2.4
Control Specifications
Human side
1) When the sensor In gate (X0) detects a person, the flashing light Green (Y1) comes ON.
2) 5 seconds after the sensor Out (X1) detects the passage of the person, the flashing light
Green (Y1) is extinguished.
Car side
1) When the sensor In gate (X2) detects a car, the flashing light Green (Y4) is lit.
2) 5 seconds after the sensor Out (X3) detects the passage of the car, the flashing light Green
(Y4) is extinguished.
3) If the car does not pass through the area between In gate (X2) and Out (X3) within 10
seconds, the flashing light Red (Y3) is lit and Buzzer (Y7) sounds.
4) As soon as the car has passed the sensor Out (X3), the flashing light Red (Y3) is
extinguished and Buzzer (Y7) stops.
Summary of Contents for MELSEC-F FX-TRN-BEG-E
Page 1: ...USER S MANUAL FX TRN BEG E Sections INTRODUCTION A EXERCISES B LADDER PROGRAMS C APPENDIX D ...
Page 2: ...FX TRN BEG E ...
Page 4: ...FX TRN BEG E ii ...
Page 6: ...FX TRN BEG E iv ...
Page 8: ...FX TRN BEG E INTRODUCTION A 2 MEMO ...
Page 10: ...FX TRN BEG E Introduction 1 A 4 MEMO ...
Page 28: ...FX TRN BEG E Outline of the Lesson Plan 2 A 22 MEMO ...
Page 40: ...FX TRN BEG E A Let s Learn the FX Series PLC 1 B 12 MEMO ...
Page 52: ...FX TRN BEG E B Let s Study the Basics 2 B 24 MEMO ...
Page 76: ...FX TRN BEG E D Beginner Challenge 4 B 48 MEMO ...
Page 90: ...FX TRN BEG E E Intermediate Challenge 5 B 62 MEMO ...
Page 106: ...FX TRN BEG E F Advanced Challenge 6 B 78 MEMO ...
Page 110: ...FX TRN BEG E Outline 1 C 4 MEMO ...
Page 162: ...FX TRN BEG E D 32 MEMO ...
Page 163: ......