881
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
C Applied Instruction List [by Instruction Type/in Alphabetic Order]
C-2 Applied instructions [in alphabetical order]
31
FN
C
275-FN
C
279
Da
ta
Tr
ans
fe
r 3
32
FN
C
280
-F
N
C
28
9
H
igh Speed
Pr
oces
si
ng 2
33
FN
C
290-FN
C
299
Ext
ensi
on Fi
le
R
egi
st
er
34
SF
C
•S
T
L
Pr
o
g
ra
m
m
in
g
35
In
te
rru
p
t
Funct
ion
36
Sp
e
cia
l De
vic
e
37
E
rro
r C
o
d
e
A
V
e
rs
ion U
p
In
fo
rm
a
tio
n
B
Ex
ec
ut
ion Ti
m
e
s
C
Appl
ic
ab
le
In
st
ru
ct
ion Li
st
E
EADD
FNC120 Floating Point Addition
480
EBCD
FNC118
Floating Point to Scientific
Notation Conversion
476
EBIN
FNC119
Scientific Notation to
Floating Point Conversion
478
ECMP
FNC110 Floating Point Compare
460
EDIV
FNC123 Floating Point Division
483
EI
FNC 04
Enable Interrupt
206
EMOV
FNC112 Floating Point Move
464
EMUL
FNC122
Floating Point
Multiplication
482
ENCO
FNC 42
Encode
299
ENEG
FNC128 Floating Point Negation
491
ESQR
FNC127 Floating Point Square Root
490
ESTR
FNC116
Floating Point to Character
String Conversion
465
ESUB
FNC121 Floating Point Subtraction
481
EVAL
FNC117
Character String to
Floating Point Conversion
471
EXP
FNC124 Floating Point Exponent
484
EZCP
FNC111
Floating Point Zone
Compare
462
F
FDEL
FNC210 Deleting Data from Tables
632
FEND
FNC 06
Main Routine Program End
208
FINS
FNC211 Inserting Data to Tables
634
FLT
FNC 49
Conversion to Floating
Point
313
FMOV
FNC 16
Fill Move
234
FOR
FNC 08
Start a FOR/NEXT Loop
213
FROM
FNC 78
Read From a Special
Function Block
426
G
GBIN
FNC171
Gray Code to Decimal
Conversion
562
GRY
FNC170
Decimal to Gray Code
Conversion
561
H
HCMOV
FNC189 High Speed Counter Move
580
HEX
FNC 83
ASCII to Hexadecimal
Conversion
441
HKY
FNC 71
Hexadecimal Input
402
HOUR
FNC169 Hour Meter
558
HSCR
FNC 54
High Speed Counter Reset
332
HSCS
FNC 53
High Speed Counter Set
327
HSCT
FNC280
High Speed Counter
Compare With Data Table
703
HSZ
FNC 55
High Speed Counter Zone
Compare
335
HTOS
FNC164
Hour to Second
Conversion
550
Mnemonic
FNC
No.
Function
Ref.
Page
I
INC
FNC 24
Increment
257
INCD
FNC 63
Incremental Drum
Sequencer
381
INITER
FNC295 Initialize ER
731
INITR
FNC292 Initialize R and ER
719
INSTR
FNC208 Character string search
626
INT
FNC129
Floating Point to Integer
Conversion
492
IRET
FNC 03
Interrupt Return
204
IST
FNC 60
Initial State
364
IVBWR
FNC274
Inverter Parameter Block
Write
691
IVCK
FNC270 Inverter Status Check
683
IVDR
FNC271 Inverter Drive
685
IVRD
FNC272 Inverter Parameter Read
687
IVWR
FNC273 Inverter Parameter Write
689
L
LD<
FNC226
Load Compare
<
645
LD<>
FNC228
Load Compare
≠
645
LD=
FNC224
Load Compare
=
645
LD>
FNC225
Load Compare
>
645
LD
<=
FNC229
Load Compare
≤
645
LD
>=
FNC230
Load Compare
≥
645
LEFT
FNC205
Extracting Character String
Data from the Left
616
LEN
FNC203
Character String Length
Detection
611
LIMIT
FNC256 Limit Control
655
LOADR
FNC290 Load From ER
709
LOG10
FNC126
Floating Point Common
Logarithm
488
LOGE
FNC125
Floating Point Natural
Logarithm
486
LOGR
FNC293 Logging R and ER
722
M
MEAN
FNC 45
Mean
306
MIDR
FNC206
Random Selection of
Character Strings
619
MIDW
FNC207
Random Replacement of
Character Strings
622
MOV
FNC 12
Move
223
MTR
FNC 52
Input Matrix
323
MUL
FNC 22
Multiplication
252
N
NEG
FNC 29
Negation
266
NEXT
FNC 09
End a FOR/NEXT Loop
214
Mnemonic
FNC
No.
Function
Ref.
Page
S
1
S
2
S
1
S
2
S
1
S
2
S
1
S
2
S
1
S
2
S
1
S
2