530
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
20 Positioning Control – FNC150 to FNC159
20.3 FNC152 – TBL / Batch Data Positioning Mode
20.3
FNC152 – TBL / Batch Data Positioning Mode
Outline
This instruction executes one specified table operation set in the data table in advance in GX Developer
(Ver.8.23Z or later).
→
For explanation of the instruction, refer to the Positioning Control Edition.
→
For cautions on using special high speed output adapters, refer to the Positioning Control Edition.
1. Instruction format
2. Set data
3. Applicable devices
S
1 : Specify a transistor output Y000, Y001, or Y002 in the main unit or Y000, Y001, Y002
*2
, or Y003
*2
in a
special high speed output adapter
*1
.
*1.
Special high speed output adapters cannot be connected to the FX
3UC
-32MT-LT.
*2.
For specifying Y002 or Y003 in a special high speed output adapter, the second special high
speed output adapter is required.
Points
• When using a relay output type FX
3U
PLC, a special high speed output adapter is required.
• Outputs of special high speed output adapters work as differential line drivers.
Explanation of function and operation
Caution on write during RUN
Write during RUN is disabled to a circuit block including TBL (FNC152) instruction.
Instruction
Description
DVIT (FNC151)
Interrupt positioning
PLSV (FNC157)
Variable speed pulse output
DRVI (FNC158)
Drive to increment
DRVA (FNC159)
Drive to absolute
Operand type
Description
Data type
Device number outputting pulse
Bit
n
Table number [1 to 100] to be executed
32-bit binary
Oper-
and
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS
T
C
D
R U
\G
V
Z Modify K
H
E
"
"
P
S
1
n
3 3
DTBL
32-bit Instruction
17 steps
Mnemonic
Operation Condition
Continuous
Operation
−
16-bit Instruction
Mnemonic
Operation Condition
FNC 152
TBL
D
D
D
Command
input
FNC152
DTBL
D
n