38
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
2.7.2
Parameter initial values and available tools for changing parameter values
*1.
These programming tools are not applicable to FX
3U
/FX
3UC
PLCs. The initial values in FX
2N
PLCs
are shown above.
*2.
Parameter values can be changed only by the F940WGOT, F94
GOT and F94
handy GOT.
*3.
Only manuals in Japanese are available for the ET-940 Series.
*4.
The initial value is 8000 steps in GX Developer Ver.8.13P to Ver.8.22Y.
*5.
GX Developer Ver.8.23Z or later is applicable.
Positioning
setting
Constant
setting
This parameter sets interrupt inputs for the maximum speed, bias speed, creep speed,
zero return speed, acceleration time, deceleration time, and DVIT instruction.
It is necessary to set the memory capacity.
Detailed
setting
This parameter sets the operation table.
It is necessary to set the memory capacity.
Others
Entry code
This parameter sets protection to prevent erroneous writing and plagiarism of a
sequence program. The entry code can be specified in 8 alphanumeric characters
among A to F and 0 to 9.
In FX
3U
and FX
3UC
PLCs Ver.2.00 or later, the second entry code (in 8 characters) can
be added to allow specification of the entry code in 16 characters.
Program title
This parameter enables to set a character string to be used as the program title.
Item
GX
Developer
Initial value
Setting range
Initial value of non-
applicable programming
tool
Display unit
FX-10P(-E)
*1
FX-20P(-E)
*1
FX-PCS/
WIN(-E)
*1
GOT-F900
Series
*2
ET-940
Series
*3
Memory
capacity (steps)
Program capacity
16000
*4
Refer to
Subsection
2.7.3.
2000
8000
8000
Katakana character
comment capacity
0
0
0
–
File register capacity
0
0
0
0
Special unit initial
value setting
*5
Not used
–
–
–
Positioning setting
*5
Not used
–
–
–
Latch range
(battery backed)
Auxiliary relay [M]
500 to 1023
0 to 1023
500 to 1023
State relay [S]
500 to 999
0 to 999
500 to 999
Counter [C] (16 bits)
100 to 199
0 to 199
100 to 199
Counter [C] (32 bits)
220 to 255
200 to 255
220 to 255
Data register [D]
200 to 511
0 to 511
200 to 511
Program title
Not registered
Refer to
Subsection
2.7.1.
–
Not registered
–
Entry code
Not registered
Not registered Not registered
–
Batteryless mode
OFF
–
OFF
–
Modem initialization specification
Not set
–
Not set
–
RUN terminal input
OFF
Not used
Not used (X0)
–
Serial port operation setting
Not set
–
Not set
–
Classification
Item
Description