723
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
33 Extension File Register Control – FNC290 to FNC299
33.4 FNC293 – LOGR / Logging R and ER
31
FN
C
275-FN
C
279
Da
ta
Tr
ans
fe
r 3
32
FN
C
280
-F
N
C
28
9
H
igh Speed
Pr
oces
si
ng 2
33
FN
C
290-FN
C
299
Ext
ensi
on Fi
le
R
egi
st
er
34
SF
C
•S
T
L
Pr
o
g
ra
m
m
in
g
35
In
te
rru
p
t
Funct
ion
36
Sp
e
cia
l De
vic
e
37
E
rro
r C
o
d
e
A
V
e
rs
ion U
p
In
fo
rm
a
tio
n
B
Ex
ec
ut
ion Ti
m
e
s
C
Appl
ic
ab
le
In
st
ru
ct
ion Li
st
Cautions
• LOGR instruction executes logging in each operation in the continuous operation type.
When logging should be executed only once by one input, use the pulse operation type.
• Caution on using a memory cassette
Flash memory is adopted in a memory cassette. Make sure to initialize the data storage area in units of
sector before starting logging.
If LOGR instruction is executed without initializing the data storage area, an operation error (error code:
K6770) may be caused.
Errors
An operation error is caused in the following cases; The error flag M8067 turns ON, and the error code is
stored in D8067.
• When any device number other than the head device number of a sector of extension file registers is set to
(error code: K6706)
• While data is written, the remaining area and the data quantity to be written are compared with each other.
If the remaining storage area is insufficient, only a limited amount of data is written. (error code: K6706)
• When the protect switch of the memory cassette is set to ON (error code: K6770)
• When the collation result after data writing is "mismatch" due to omission of initialization or for another
reason (error code: K6770)
When this error occurs, the current values (data) of extension registers (R) may be lost. To avoid the data
loss, back up the data of extension registers (R) in advance using the following procedure:
1) Set the PLC mode to STOP.
2) Create a new project in GX Developer.
This step is not necessary if it is alright to overwrite the current project.
3) Read the contents of extension registers (R) to GX Developer.
[1]Select "Online"
→
"Read from PLC..." to
display "Read from PLC" window.
[2]Click "Parameter" and "Device data" to
put a check mark next to each of them.
[3]Click [Execute] button to execute reading.
[4]When reading is completed, save the
project.
*1.
In some versions of GX Developer, "FX3UC" is
offered as the PLC type.
n
FNC292
INITR
D
1
Logging data storage area initialization
command input
*1
*2
*1 Specify the same device as in LOGR instruction.
*2 Specify the same number as (n) in LOGR instruction.
D
1
S
FX3U(C)*1