811
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
36 Operation of Special Devices (M8000 -, D8000 -)
36.1 Special Device List (M8000 -, D8000 -)
31
FN
C
275-FN
C
279
Da
ta
Tr
ans
fe
r 3
32
FN
C
280
-F
N
C
28
9
H
igh Speed
Pr
oces
si
ng 2
33
FN
C
290-FN
C
299
Ext
ensi
on Fi
le
R
egi
st
er
34
SF
C
•S
T
L
Pr
o
g
ra
m
m
in
g
35
In
te
rru
p
t
Funct
ion
36
Sp
e
cia
l De
vic
e
37
E
rro
r C
o
d
e
A
V
e
rs
ion U
p
In
fo
rm
a
tio
n
B
Ex
ec
ut
ion Ti
m
e
s
C
Appl
ic
ab
le
In
st
ru
ct
ion Li
st
Timing Clock (Refer to Section 24.3 for details.) and Positioning [FX
3U
and FX
3UC
PLCs] (Refer to Positioning Control Edition for details.)
[M]8330
DUTY (FNC186) instruction: Timing clock output 1
3
3
*1
D8330
–
–
–
–
–
[M]8331
DUTY (FNC186) instruction: Timing clock output 2
3
3
*1
D8331
–
–
–
–
–
[M]8332
DUTY (FNC186) instruction: Timing clock output 3
3
3
*1
D8332
–
–
–
–
–
[M]8333
DUTY (FNC186) instruction: Timing clock output 4
3
3
*1
D8333
–
–
–
–
–
[M]8334
DUTY (FNC186) instruction: Timing clock output 5
3
3
*1
D8334
–
–
–
–
–
[M]8335
Not used
–
–
–
–
–
–
–
–
M 8336
*2
DVIT (FNC151) instruction:
Interrupt input specification function enabled
3
3
*3
D8336
–
–
–
–
–
[M]8337
Not used
–
–
–
–
–
–
–
–
M 8338
PLSV (FNC157) instruction:
Acceleration/deceleration operation
3
3
*1
–
–
–
–
–
–
[M]8339
Not used
–
–
–
–
–
–
–
–
[M]8340
[Y000] Pulse output monitor (ON: BUSY/ OFF: READY)
3
3
–
–
–
–
–
–
M 8341
*2
[Y000] Clear signal output function enable
3
3
–
–
–
–
–
–
M 8342
*2
[Y000] Zero return direction specification
3
3
–
–
–
–
–
–
M 8343
[Y000] Forward limit
3
3
–
–
–
–
–
–
M 8344
[Y000] Reverse limit
3
3
–
–
–
–
–
–
M 8345
*2
[Y000] DOG signal logic reverse
3
3
–
–
–
–
–
–
M 8346
*2
[Y000] Zero point signal logic reverse
3
3
–
–
–
–
–
–
M 8347
*2
[Y000] Interrupt signal logic reverse
3
3
–
–
–
–
–
–
[M]8348
[Y000] Positioning instruction activation
3
3
–
–
–
–
–
–
M 8349
*2
[Y000] Pulse output stop command
3
3
–
–
–
–
–
–
[M]8350
[Y001] Pulse output monitor (ON: BUSY/ OFF: READY)
3
3
–
–
–
–
–
–
M 8351
*2
[Y001] Clear signal output function enable
3
3
–
–
–
–
–
–
M 8352
*2
[Y001] Zero return direction specification
3
3
–
–
–
–
–
–
M 8353
[Y001] Forward limit
3
3
–
–
–
–
–
–
M 8354
[Y001] Reverse limit
3
3
–
–
–
–
–
–
M 8355
*2
[Y001] DOG signal logic reverse
3
3
–
–
–
–
–
–
M 8356
*2
[Y001] Zero point signal logic reverse
3
3
–
–
–
–
–
–
M 8357
*2
[Y001] Interrupt signal logic reverse
3
3
–
–
–
–
–
–
[M]8358
[Y001] Positioning instruction activation
3
3
–
–
–
–
–
–
M 8359
*2
[Y001] Pulse output stop command
3
3
–
–
–
–
–
–
[M]8360
[Y002] Pulse output monitor (ON: BUSY/ OFF: READY)
3
3
–
–
–
–
–
–
M 8361
*2
[Y002] Clear signal output function enable
3
3
–
–
–
–
–
–
M 8362
*2
[Y002] Zero return direction specification
3
3
–
–
–
–
–
–
M 8363
[Y002] Forward limit
3
3
–
–
–
–
–
–
M 8364
[Y002] Reverse limit
3
3
–
–
–
–
–
–
M 8365
*2
[Y002] DOG signal logic reverse
3
3
–
–
–
–
–
–
M 8366
*2
[Y002] Zero point signal logic reverse
3
3
–
–
–
–
–
–
M 8367
*2
[Y002] Interrupt signal logic reverse
3
3
–
–
–
–
–
–
[M]8368
[Y002] Positioning instruction activation
3
3
–
–
–
–
–
–
M 8369
*2
[Y002] Pulse output stop command
3
3
–
–
–
–
–
–
*1.
Available in Ver. 2.00 or later.
*2.
Cleared when PLC switches from RUN to STOP.
*3.
Available in the Ver. 1.30 or later.
Number and name
Operation and function
Applicable model
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX
2NC