[6-11 Standard Operation Data (Reference Data) ]
- 144 -
HWE14040
GB
Packaged unit model
PUHY-P500YSKB-A1
Outdoor unit model
PUHY-P250YKB-A1
PUHY-P250YKB-A1
Conditions
Ambient temperature
(cooling)
Indoor
DB/WB
26.7°C/19.4°C [80°F/67°F]
Outdoor
35°C/- [95°F/-]
Ambient temperature
(heating)
Indoor
DB/WB
21.1°C/- [70°F/-]
Outdoor
8.3°C/6.1°C [47°F/43°F]
Indoor unit
Number of units connected
Unit
4
Number of units in operation
4
Model
-
125/125/125/125
Piping
Main pipe
m [ft]
5
[16-3/8]
Branch pipe
10
[32-3/4]
Total pipe length
45
[147-5/8]
Fan speed
-
Hi
Refrigerant charge
kg [lbs-oz]
25
[56]
Outdoor unit
Voltage
V
400
Cooling operation
Outdoor unit
Electric current
A
28.4
Compressor frequency
Hz
65
65
LEV open-
ing
Indoor unit
Pulse
325/325/325/325
SC (LEV1)
100
100
LEV2
2100
2100
Pressure
High pressure (after O/S)/Low pressure (before accumula-
tor)
MPa [psi]
2.83/0.84
[410/122]
2.83/0.84
[410/122]
Section
tempera-
tures
Outdoor unit
Discharge (TH4)
°C [°F]
74
[165]
74
[165]
Heat exchanger outlet (TH3)
46
[115]
46
[115]
Accumulator inlet
10
[50]
10
[50]
Accumulator outlet
10
[50]
10
[50]
SCC outlet (TH6)
26
[79]
26
[79]
Compressor inlet
14
[57]
14
[57]
Compressor shell bottom
38
[100]
38
[100]
Indoor unit
LEV inlet
25
[77]
25
[77]
Heat exchanger outlet
10
[50]
10
[50]
Heating operation
Outdoor unit
Electric current
A
29.3
Compressor frequency
Hz
71
71
LEV open-
ing
Indoor unit
Pulse
332/332/332/332
SC (LEV1)
0
LEV2
2100
2100
Pressure
High pressure (after O/S)/Low pressure (before accumula-
tor)
MPa [psi]
2.85/0.64
[413/93]
2.85/0.64
[413/93]
Section
tempera-
tures
Outdoor unit
Discharge (TH4)
°C [°F]
75
[167]
75
[167]
Heat exchanger outlet (TH3)
-2
[28]
-2
[28]
Accumulator inlet
-2
[28]
-2
[28]
Accumulator outlet
-2
[28]
-2
[28]
Compressor inlet
-2
[28]
-2
[28]
Compressor shell bottom
40
[104]
40
[104]
Indoor unit
LEV inlet
37
[99]
37
[99]
Heat exchanger inlet
73
[163]
73
[163]
Summary of Contents for PUHY-P1000
Page 1: ......
Page 11: ... 2 HWE14040 GB ...
Page 27: ... 18 HWE14040 GB ...
Page 40: ... 2 6 System Connection Example 31 HWE14040 GB 2 Restrictions ...
Page 61: ... 52 HWE14040 GB ...
Page 75: ... 66 HWE14040 GB ...
Page 93: ... 84 HWE14040 GB ...
Page 121: ... 112 HWE14040 GB ...
Page 171: ... 6 11 Standard Operation Data Reference Data 162 HWE14040 GB ...
Page 243: ... 7 9 Error Code Definitions and Solutions Codes 7000 7999 234 HWE14040 GB ...
Page 297: ... 288 HWE14040 GB ...
Page 334: ......