[3-2 External Appearance and Internal Components of Indoor Unit ]
4
-
chapter 3
BS_03_C
3 Major Compon
ent
s
, Their Fun
ct
io
ns
a
n
d
Re
frig
e
ra
n
t
Circ
ui
ts
(2) PFD-P500VM-E model
50
100
140
50
50
390
100
68
124
135
Refrig. piping <liquid> in 2 refrig. circuit system ø 9.52 braze No.1
Refrig. piping <gas> in 2 refrig. circuit
system P500:ø 22.2 braze No.1
Refrig. piping <liquid> ø 15.88 braze
Refrig. piping <gas> ø 28.58 braze
Hole for No.2 gas pipe
connecting(ø 42) in 2
refrig. circuit system
Hole for No.2 liquid pipe
connecting(ø 24) in 2
refrig. circuit system
Hole for liquid pipe connecting(ø 34)
Hole for No.1 liquid pipe connecting
(ø 24) in 2 refrig. circuit system
Bolt holes:8-ø 18
Hole for No.1 gas pipe connecting(ø 42)
in 2 refrig. circuit system
Hole for gas pipe connecting(ø 48)
Main drain piping connecting<Rp1-1/4>
<Accessory>
· Lifting bolts
······4pc.
· Front panel opening and closing key
······1pc.
Air inlet
Service space
Indoor unit
Pipe execution
space
Panel opening
and closing
dimension
Indoor unit
Unit surface
figure
Service space
400 or more
Unit front
figure
1000 or more *1
200 or more
*1.
It is necessary for the removal
of the panel beyond 600mm.
500 or more
710
Refrig. piping <gas> in 2 refrig. circuit
system P500:ø 22.2 braze No.2
680
<2-ø 32 knock out
hole>
<ø 32 knock out hole>
Air outlet
Air inlet
Power supply
:White
Operating :Green
Check :Y
ellow
Failure1 :Red
Failure2 :Red
<Normal/Local>
(Accessory)
<view from
A>
Air
outlet
Hole for liquid side pipe connecting
or No.1 gas side pipe connecting(ø 42)
in 2 refrig. circuit system
Hole for No.2 gas side pipe connecting(ø 42)
in 2 refrig. circuit system
100
100
1780
1940
100
20
20
20
65
321
100
410
359
241
740
359
580
305
320
220
370
20
Emergency drain piping connection <Rp1-1/4>
Hole for No.1 liquid side pipe connecting
(ø 24) in 2 refrig. circuit system
Hole for the power supply(ø 60)
1950
780
Hole for gas side pipe connecting or
No.2 liquid side pipe connecting(ø 48)
in 2 refrig. circuit system
440
Air
outlet
185
135
Refrig. piping <liquid> in 2 refrig. circuit
system ø 9.52 braze No.2
68
120
Hole for the control wiring <ø 32 knock out hole>
Hole for the power supply <ø 32 knock out hole>
150
81
Hole for the control wiring(ø 60)
Panel
68
Lifting bolts
171
A
Control box
Lamp
Filter
Remote controller
838
Hole for the control wiring
1980
124
68
Hole for the power
supply(Body)
Changeover switch (SW9)
Unit : mm
Note
1.
Be sure to set up a trap for Emergency
drain
piping.
(T
rap height:beyond 100mm)
(T
rap is not necessary for main drain piping.)
2.
Due to continuing improvement,
specifications may be subject to
change without notice.
3.
Amputate a gas pipe/liquid pipe in the
fixed height at the time of 2 refrigerant
circuit connection, and connect it with
the local pipe.
0000004493.BOOK 4 ページ 2018年1月5日 金曜日 午前9時11分
Summary of Contents for PFD-P250VM-E
Page 11: ...GB_BS_01_C 0000004491 BOOK 2 ページ 2017年12月26日 火曜日 午後1時10分 ...
Page 27: ...GB_BS_02_C 0000004492 BOOK 2 ページ 2018年1月5日 金曜日 午前10時12分 ...
Page 49: ...GB_BS_03_C 0000004493 BOOK 2 ページ 2018年1月5日 金曜日 午前9時11分 ...
Page 71: ...GB_BS_04_C 0000004494 BOOK 2 ページ 2017年12月26日 火曜日 午前11時43分 ...
Page 89: ...GB_BS_05_C 0000004495 BOOK 2 ページ 2017年12月26日 火曜日 午前11時44分 ...
Page 117: ...GB_BS_06_C 0000004496 BOOK 2 ページ 2017年12月26日 火曜日 午前11時45分 ...
Page 281: ...GB_BS_09_A1 0000004538 BOOK 2 ページ 2017年12月25日 月曜日 午後7時48分 ...
Page 299: ...GB_BS_10_C 0000004550 BOOK 2 ページ 2017年12月26日 火曜日 午後12時1分 ...