Ethernet interface module
MELSEC-WS
36
Check the
Listen to
checkbox.
Enter the
Port
number on which the application will connect.
Select the update mode:
Enable COS update
or
Enable auto update and
COS
.
If you have selected
Enable auto update and COS
, select the
Update rate
in
ms. (Configurable range: 40 to 65535)
Select which data sets shall be updated: Check the
Update Dataset n
checkbox.
Ethernet interface module writes to Address/Port (Auto update) mode
The Ethernet interface module can be configured to automatically update the data
set information (i.e. the application does not need to send any request messages as
it would do in polling mode) once the connection to the application has been made.
The configuration settings are available via the Setting and Monitoring Tool or via the
TCP/IP interface itself. Using one interface does not disable the other: The auto
update mode could be enabled via Setting and Monitoring Tool and disabled via
TCP/IP command, for example.
Configuration via TCP/IP interface
This command message is sent by an application to the Ethernet interface module
to configure the auto update mode. This message can be used to either disable or
enable the auto update mode directly through the TCP/IP interface.
Figure 17:
TCP/IP configuration for
polling mode
Summary of Contents for Melsec WS Series
Page 1: ...Safety Controller Ethernet Interface Module User s Manual WS0 GETH ...
Page 2: ......
Page 89: ...Procedures before operation MELSEC WS 86 ...
Page 90: ...MELSEC WS Procedures before operation 87 ...
Page 91: ...Procedures before operation MELSEC WS 88 ...
Page 97: ...Procedures before operation MELSEC WS 94 ...
Page 98: ...MELSEC WS Procedures before operation 95 ...
Page 99: ...Procedures before operation MELSEC WS 96 ...
Page 141: ......