104
2 POSITIONING DEDICATED SIGNALS
2.2 Data Registers
JOG speed setting registers
This area stores the JOG operation speed data.
Device No.
Signal name
MELSEC iQ-R Motion
device assignment
Q series Motion compatible
device assignment
D35120, D35121
D640, D641
Axis 1 JOG speed setting register
D35122, D35123
D642, D643
Axis 2 JOG speed setting register
D35124, D35125
D644, D645
Axis 3 JOG speed setting register
D35126, D35127
D646, D647
Axis 4 JOG speed setting register
D35128, D35129
D648, D649
Axis 5 JOG speed setting register
D35130, D35131
D650, D651
Axis 6 JOG speed setting register
D35132, D35133
D652, D653
Axis 7 JOG speed setting register
D35134, D35135
D654, D655
Axis 8 JOG speed setting register
D35136, D35137
D656, D657
Axis 9 JOG speed setting register
D35138, D35139
D658, D659
Axis 10 JOG speed setting register
D35140, D35141
D660, D661
Axis 11 JOG speed setting register
D35142, D35143
D662, D663
Axis 12 JOG speed setting register
D35144, D35145
D664, D665
Axis 13 JOG speed setting register
D35146, D35147
D666, D667
Axis 14 JOG speed setting register
D35148, D35149
D668, D669
Axis 15 JOG speed setting register
D35150, D35151
D670, D671
Axis 16 JOG speed setting register
D35152, D35153
D672, D673
Axis 17 JOG speed setting register
D35154, D35155
D674, D675
Axis 18 JOG speed setting register
D35156, D35157
D676, D677
Axis 19 JOG speed setting register
D35158, D35159
D678, D679
Axis 20 JOG speed setting register
D35160, D35161
D680, D681
Axis 21 JOG speed setting register
D35162, D35163
D682, D683
Axis 22 JOG speed setting register
D35164, D35165
D684, D685
Axis 23 JOG speed setting register
D35166, D35167
D686, D687
Axis 24 JOG speed setting register
D35168, D35169
D688, D689
Axis 25 JOG speed setting register
D35170, D35171
D690, D691
Axis 26 JOG speed setting register
D35172, D35173
D692, D693
Axis 27 JOG speed setting register
D35174, D35175
D694, D695
Axis 28 JOG speed setting register
D35176, D35177
D696, D697
Axis 29 JOG speed setting register
D35178, D35179
D698, D699
Axis 30 JOG speed setting register
D35180, D35181
D700, D701
Axis 31 JOG speed setting register
D35182, D35183
D702, D703
Axis 32 JOG speed setting register
D35184, D35185
Axis 33 JOG speed setting register
D35186, D35187
Axis 34 JOG speed setting register
D35188, D35189
Axis 35 JOG speed setting register
D35190, D35191
Axis 36 JOG speed setting register
D35192, D35193
Axis 37 JOG speed setting register
D35194, D35195
Axis 38 JOG speed setting register
D35196, D35197
Axis 39 JOG speed setting register
D35198, D35199
Axis 40 JOG speed setting register
D35200, D35201
Axis 41 JOG speed setting register
D35202, D35203
Axis 42 JOG speed setting register
D35204, D35205
Axis 43 JOG speed setting register
D35206, D35207
Axis 44 JOG speed setting register
D35208, D35209
Axis 45 JOG speed setting register
D35210, D35211
Axis 46 JOG speed setting register
D35212, D35213
Axis 47 JOG speed setting register
D35214, D35215
Axis 48 JOG speed setting register