454
7 AUXILIARY AND APPLIED FUNCTIONS
7.7 Pressure Control
Device assignment of pressure profile data
Pressure profile data is stored to the device that is set as the pressure profile start device as follows.
Offset
Name
Description
Range
+0
Feed data
Number of steps
Set the number of steps for feed data.
Set the data for the set number of steps.
1 to 16
+1
Unusable
Set 0.
0
+2
Step No.0
End address (SE)
Set the final intended position in feed/dwell operation.
Cannot be changed while running.
-2147483648 to 2147483647
+3
+4
Start speed (V0)
Set the start speed limit value for feed operation.
Can be changed during feed operation.
mm : 0 to 600000000
inch : 0 to 600000000
pulse : 0 to 2147483647
+5
+6
Start pressure (PR0)
Set the start pressure command value for feed operation.
Cannot be changed while running.
0 to 32767
+7
+8
Speed limit value
time constant
Set the acceleration/deceleration time for the speed limit value.
Set the time taken for speed limit value to reach the pressure
control speed limit reference from 0.
0 to 8388608 [ms]
+9
+10
Pressure command
time constant
Set the pressurization/depressurization time for the pressure
command. Set the time taken for pressure command to reach
the pressure command reference from 0.
0 to 8388608 [ms]
+11
+12
Step No.1
Switching address
(S1)
Set the switching address of the speed setting/pressure for feed
operation.
Cannot be changed while running.
-2147483648 to 2147483647
+13
+14
Switching speed
(V1)
Set the speed limit value for feed operation.
Can be changed during feed operation.
mm : 0 to 600000000
inch : 0 to 600000000
pulse : 0 to 2147483647
+15
+16
Switching pressure
(PR1)
Set the pressure command for feed operation.
Cannot be changed while running.
0 to 32767
+17
+18
Unusable
Set 0.
0
+19
+20
+21
+22
Step No.2
Switching address
(S2)
Data for the number of steps set in "Number of steps" is valid.
Setting of data for steps after the set number of steps is not
necessary.
-2147483648 to 2147483647
+23
+24
Switching speed
(V2)
mm : 0 to 600000000
inch : 0 to 600000000
pulse : 0 to 2147483647
+25
+26
Switching pressure
(PR2)
0 to 32767
+27
+28
Unusable
0
+29
+30
+31
+152
Step No.15
Switching address
(S15)
-2147483648 to 2147483647
+153
+154
Switching speed
(V15)
mm : 0 to 600000000
inch : 0 to 600000000
pulse : 0 to 2147483647
+155
+156
Switching pressure
(PR15)
0 to 32767
+157
+158
Unusable
0
+159
+160
+161