![Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual Download Page 231](http://html.mh-extra.com/html/mitsubishi-electric/melsec-iq-r16mtcpu/melsec-iq-r16mtcpu_programming-manual_239141231.webp)
3 PARAMETERS FOR POSITIONING CONTROL
3.13 Parameter Block
229
3
When the stop command turns ON during acceleration processing of advanced S-curve acceleration/
deceleration, in order to maintain smoothness of acceleration, the speed will continue to increase until
acceleration reaches zero.
Use the rapid stop command if an increase in speed is not desired.
■
Rapid stop processing
• Rapid stop during acceleration
When the rapid stop command turns ON during acceleration, acceleration immediately goes to zero, and rapid stop
deceleration processing is executed. (Deceleration is abrupt.)
• Rapid stop during deceleration
When the rapid stop command turns ON during deceleration, the negative acceleration is decreased, and the rapid stop
deceleration processing is executed.
0
0
Setting speed
Speed
Acceleration
AmaxA
EmaxA
Time
Time
OFF
ON
Control during rapid
stop command OFF
Control during rapid
stop command OFF
Rapid stop
processing
[Rq.1141] Rapid stop command
(R: 32n/Q: M3201+20n)
0
0
Setting speed
Speed
Acceleration
DmaxA
EmaxA
Time
Time
OFF
ON
Control during rapid
stop command OFF
Control during rapid
stop command OFF
Rapid stop
processing
[Rq.1141] Rapid stop command
(R: 32n/Q: M3201+20n)
Summary of Contents for MELSEC iQ-R16MTCPU
Page 2: ......
Page 477: ...APPENDICES Appendix 1 Processing Times of the Motion CPU 475 A MEMO ...
Page 481: ......