5 POSITIONING CONTROL
5.1 Basics of Positioning Control
267
5
S-curve ratio can be set by the servo program is following two methods.
■
Specification by numerical value
S-curve ratio is set a numerical value from 0 to 100.
■
Indirect specification by devices
S-curve ratio is set by devices.
Refer to the following for the setting range of usable devices.
MELSEC iQ-R Motion controller Programming Manual (Common)
INC-2
Axis
Axis
2,
1,
250000
Vector speed
1000
S-curve ratio
80
<K 10>
2 axes linear interpolation control
•
Axis used . . . . . . . . . . .
. . . . . .
Axis 1, Axis 2
Positioning speed . . . . . . . 1000
•
Axis 1 . . . 100000
•
Axis 2 . . . 250000
•
Travel value to
stop position
S-curve ratio . . . . . . . . . . . 80[%]
100000
Indirect specification by word devices
<K 10>
1 axis linear positioning control
•
Axis used . . . . . . . . . . . . .
. . . . . .
Axis 1
30000
•
Positioning address
. . . . . . . . . . 400000
Positioning speed
ABS-1
Axis
1,
30000
Speed
400000
S-curve ratio
D3487