90
2 POSITIONING DEDICATED SIGNALS
2.2 Data Registers
■
Q series Motion compatible device assignment
For devices on axis 1 to 32, use Q series Motion compatible device assignment.
For devices on axis 33 to 64, machine control device (D52896 to D53151), and machine status (D53168 to D54191), use
MELSEC iQ-R Motion device assignment.
*1 It can be used as a user device.
Total number of user device points
• 10096 points
Device No.
Symbol
Purpose
Reference
D0
to
[Md.20], [Md.25], [Md.34],
[Md.35], [Md.101], [Md.102],
[Md.1003] to [Md.1006], [Md.1008],
[Md.1011], [Md.1012]
Axis monitor device
(20 points
32 axes)
D640
to
[Cd.1110]
JOG speed setting registers
(2 points
32 axes)
Page 104 JOG speed setting registers
D704
to
[Cd.1096] to [Cd.1104]
Common device (Command signal)
(54 points)
D758
to
Unusable
(42 points)
D800
to
User device
(9440 points)
D10240
to
System area
(2040 points)
D12280
to
[Md.300] to [Md.303]
Servo input axis monitor device
(10 points
32 axes)
Page 106 Servo input axis monitor device
D12600
to
[Md.340] to [Md.348]
Command generation axis monitor device
(20 points
32 axes)
Page 110 Command generation axis
D13240
to
[Md.320] to [Md.324], [Md.326],
[Md.327]
Synchronous encoder axis monitor device
(20 points
12 axes)
Page 115 Synchronous encoder axis
D13480
to
Unusable
(120 points)
D13600
to
[Md.400] to [Md.402],
[Md.406] to [Md.412], [Md.422],
[Md.425]
Output axis monitor device
(30 points
32 axes)
Page 118 Output axis monitor device
D14560
to
Unusable
(40 points)
D14600
to
[Pr.302]
Servo input axis control device
(2 points
32 axes)
Page 108 Servo input axis control device
D14664
to
Unusable
(16 points)
D14680
to
[Cd.340], [Pr.348]
Command generation axis control device
(4 points
32 axes)
Page 113 Command generation axis control
D14808
to
Unusable
(12 points)
D14820
to
[Pr.326], [Cd.320] to [Cd.322],
[Cd.325]
Synchronous encoder axis control device
(10 points
12 axes)
Page 117 Synchronous encoder axis control
D14940
to
Unusable
(60 points)
D15000
to
[Pr.400] to [Pr.414],
[Pr.418] to [Pr.431],
[Pr.434] to [Pr.442], [Pr.444],
[Pr.445], [Pr.447], [Pr.448],
[Pr.460] to [Pr.468],
[Pr.490] to [Pr.493],
[Cd.407] to [Cd.409]
Output axis control device
(150 points
32 axes)
Page 121 Output axis control device
D19800
to
Unusable
(24 points)
D19824
to
D20479
Unusable
(656 points)