3 PARAMETERS FOR POSITIONING CONTROL
3.13 Parameter Block
219
3
• If the rapid stop deceleration time is long than the deceleration time, an overrun may occur.
• If a large value than deceleration time is set as the rapid stop deceleration time for the parameter block and
positioning data of servo program, a warning will occur. However, writing to the Motion CPU is possible.
■
Rapid stop deceleration time
Deceleration time
When the rapid stop cause occurs during deceleration, the axis decelerates to a stop in the rapid stop time.
V
t
Real deceleration time
Speed command
[Rq.1141] Rapid stop command
(R: 32n/Q: M3201+20n)
The deceleration distance increases
by rapid stop command.
OFF
ON
Deceleration stop processing
Rapid stop detection processing
Stop
Rapid stop cause